Sulfonated sodium alginate-doped PEDOT conductive antifreeze double-network hydrogel for flexible strain sensing
Rubai Luo , Tongtong Qin , Haibin Li , Ke Zhang , Jingbo Hu , Tao Bai , Xing Zhou , Weiyan Wang , Lu Li
AIMS Materials Science ›› 2026, Vol. 13 ›› Issue (4) : 857 -881.
Conductive hydrogels, which integrate high mechanical flexibility with electrical conductivity, have attracted considerable attention for applications in flexible electronic skins and wearable health-monitoring systems. Poly(3,4-ethylenedioxythiophene) (PEDOT) is widely utilized in conductive hydrogels and flexible electronic devices owing to its excellent electrical conductivity, chemical stability, and environmental durability. However, the poor dispersibility, severe aggregation tendency, and limited film-forming capability of conventional PEDOT, together with the freezing-induced brittleness of conventional hydrogels at low temperatures, significantly restrict their practical applications. Herein, PEDOT was doped and stabilized using sulfonated sodium alginate (SSA), and poly(vinyl alcohol) (PVA), polyacrylamide (PAM), ethylene glycol (EG), and an ionic liquid (IL) were introduced to construct a PVA/PAM/EG/PEDOT:SSA/IL (PPEPSI) conductive double-network hydrogel with excellent freeze resistance. The results demonstrated that SSA effectively inhibited PEDOT aggregation. When the 3,4-ethylenedioxythiophene (EDOT)-to-SSA feed ratio was optimized to 1.0 mL·g-1, the average particle size of the PEDOT dispersion was reduced to 0.32 μm, accompanied by an electrical conductivity of 8.12 S·m-1. The resulting PPEPSI hydrogel exhibited a dense three-dimensional network structure. With the incorporation of 10 wt% IL, the hydrogel achieved a tensile strength of 436 kPa, an elongation at break of 218%, and an electrical conductivity of 21.65 mS/cm. Furthermore, owing to the synergistic effects of EG and IL, the hydrogel maintained excellent flexibility at −20 °C. As a flexible strain sensor, the hydrogel exhibited a maximum gauge factor (GF) of 3.06 over a strain range of 0–240%, with response and recovery times of 0.216 and 0.243 s, respectively. The sensor enabled real-time monitoring of multiscale human motions and handwriting signals, while structural reconstruction of the hydrogel network was achieved through thermal and low-temperature treatments. In addition, the hydrogel precursor exhibited shear-thinning behavior, enabling the fabrication of complex patterns via 3D printing. These results demonstrate the potential of the PPEPSI hydrogel for applications in flexible electronics and smart wearable devices.
strain sensor / conductive hydrogel / PEDOT / freeze resistance / human motion monitoring
| [1] |
|
| [2] |
|
| [3] |
|
| [4] |
|
| [5] |
|
| [6] |
|
| [7] |
|
| [8] |
Xie X, Chen X, Zhou J, |
| [9] |
|
| [10] |
|
| [11] |
|
| [12] |
|
| [13] |
|
| [14] |
|
| [15] |
Du H, Chen X, Gong H, |
| [16] |
|
| [17] |
|
| [18] |
|
| [19] |
|
| [20] |
K N, Rout CS (2021) Conducting polymers: A comprehensive review on recent advances in synthesis, properties and applications. RSC Adv 11: 5659-5697. https://doi.org/10.1039/d0ra07800j |
| [21] |
|
| [22] |
|
| [23] |
|
| [24] |
|
| [25] |
|
| [26] |
|
| [27] |
Yousefian H, |
| [28] |
|
| [29] |
|
| [30] |
|
| [31] |
|
| [32] |
Xie X, Sun S, Wang H, |
| [33] |
|
| [34] |
|
| [35] |
|
| [36] |
|
| [37] |
Zhang Z, Chen G, Xue Y, |
| [38] |
|
| [39] |
|
| [40] |
|
| [41] |
|
| [42] |
|
| [43] |
|
| [44] |
|
| [45] |
|
| [46] |
|
| [47] |
|
| [48] |
|
| [49] |
|
| [50] |
|
| [51] |
|
| [52] |
|
| [53] |
|
| [54] |
Choi G, Ali F, Kim K, |
| [55] |
|
| [56] |
|
| [57] |
|
| [58] |
|
| [59] |
Lan Y, Yao K, Shi P, |
| [60] |
|
| [61] |
|
| [62] |
|
| [63] |
|
| [64] |
|
| [65] |
|
| [66] |
|
| [67] |
|
| [68] |
|
| [69] |
|
| [70] |
|
| [71] |
|
| [72] |
|
| [73] |
|
/
| 〈 |
|
〉 |