CMOS cameras: state-of-the-art technology for neuronal functional imaging with high spatiotemporal resolution
Marco Canepari
AIMS Biophysics ›› 2025, Vol. 12 ›› Issue (4) : 499−509
In the last decade, complementary metal-oxide semi-conductor (CMOS) cameras became the state-of-the-art technology in many biological applications, and the ability to reach high acquisition rates represents one of the characteristics that outperform previous technologies. In this review, I concentrated on neuronal functional imaging (voltage and/or ions) that requires recording fluorescence from multiples sites of a neuron or of a network at kHz rates to sample signals associated with neuronal excitability. After introducing the physical constrains of this type of imaging and reviewing the technologies used in the past, I analysed how CMOS can address the challenge of neuronal functional imaging. I focused on the characteristics of two CMOS cameras that are in use in my laboratory: DaVinci2K and Kinetix. DaVinci2K achieves high acquisitions rates at 14-bit depth by using parallel processing from 16 sub-sensors whereas Kinetix achieves higher spatiotemporal resolution by sampling fluorescence at 8-bit depth, but at the cost of decreasing the dynamic range which represents a limitation in several experimental scenarios. I present comparable membrane potential imaging recordings of action potentials from the axon initial segment, which were achieved at 20 kHz with the two cameras. Finally, I conclude the review with some perspective considerations on future availability of CMOS cameras that may overcome the performance of present devices and the limitations in developing optimal devices for biological and biomedical applications.
CMOS / imaging / neuron / fluorescence / membrane potential
| [1] |
|
| [2] |
|
| [3] |
|
| [4] |
Rubart M (2004) Two-photon microscopy of cells and tissue. Circ Res 95: 1154-1166. https://doi.org/10.1161/01.RES.0000150593.30324.42 |
| [5] |
|
| [6] |
|
| [7] |
|
| [8] |
|
| [9] |
Zecević D (1996) Multiple spike-initiation zones in single neurons revealed by voltage-sensitive dyes. Nature 381: 322-325. https://doi.org/10.1038/381322a0 |
| [10] |
Takamatsu T, Wier WG (1990) High temporal resolution video imaging of intracellular calcium. Cell Calcium 11: 111-120. https://doi.org/10.1016/0143-4160(90)90064-2 |
| [11] |
|
| [12] |
Mammano F, Canepari M, Capello G, |
| [13] |
|
| [14] |
|
| [15] |
|
| [16] |
|
| [17] |
|
| [18] |
|
| [19] |
|
| [20] |
|
| [21] |
|
| [22] |
|
| [23] |
|
| [24] |
|
| [25] |
|
| [26] |
|
| [27] |
|
| [28] |
|
| [29] |
|
| [30] |
|
| [31] |
|
| [32] |
|
| [33] |
|
| [34] |
|
| [35] |
|
| [36] |
|
| [37] |
|
| [38] |
|
| [39] |
|
| [40] |
|
| [41] |
|
| [42] |
|
| [43] |
|
| [44] |
|
| [45] |
|
| [46] |
|
| [47] |
|
/
| 〈 |
|
〉 |