Abstract

Mycotoxin contamination of food and feed is a significant health hazard in humid areas of the world. Fungal development can be halted if the water activity of dried products is kept below 0.65. This preliminary study evaluates the color response and response time of a low-cost humidity indicator that estimates water activity. The DryCardTM has a consistent color response to relative humidity and its response time is fast enough to be used in practical situations for estimating water activity. The card comes with use instructions and it can be reused many times. It is a crucial tool to assist smallholder farmers and traders in ensuring their crops have been adequately dried.

Keywords

Aflatoxin / water activity / equilibrium relative humidity / grains / dried food

Cite this article

Download citation ▾
James F. Thompson, Michael S. Reid, Lucia Felix, Irwin Donis-Gonzalez, Bertha Mjawa, Jane Ambuko. DryCard TM-A Low-Cost Dryness Indicator for Dried Products. AIMS Agriculture and Food, 2017, 2 (4) : 339-344 DOI:10.3934/agrfood.2017.4.339

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

de Beuchat LR (1981) Microbial stability as affected by water activity. Cereal Foods World 26: 345-361.

[2]

Grace D,(2015) Food Safety in Low and Middle Income Countries. Int J Environ Res Public Health 12: 10490-10507.

[3]

Bradford KJ, P Dahal, P Bello (2016) Using Relative Humidity Indicator Paper to Measure Seed and Commodity Moisture Contents. A&EL 1: 160018.

[4]

Tubbs T, C Woloshuk, K E Ileleji (2017) A simple low-cost method of determining whether it is safe to store maize. AIMS Agric Food 1: 43-55.

[5]

Solomon ME (1945) The use of cobalt salts as indicators of humidity and moisture. Ann Appl Biol 32: 75-85.

[6]

Miyauchi A, F Yokota, M Endo (2001) Quantitative Tristimulus Colorimetry for the Determination of Humidity. Anal Sci: i1651-i1653.

[7]

Greenspan L (1976) Humidity fixed points of binary saturated aqueous solutions. J Res Nat Bur Stand 81A: 89-96.

[8]

Carr DS, B L Harris (1949) Solutions for maintaining constant relative humidity. Ind Eng Chem 41: 2104-2015.

[9]

European Chemicals Agency, 2017. Available from: https://echa.europa.eu/substance-information/-/substanceinfo/100.028.718.

PDF (656KB)

0

Accesses

0

Citation

Detail

Sections
Recommended

/

〈 〉