Granulation process analysis technologies and potential applications in traditional Chinese medicine

Tongcan Cui, Yizhe Hou, Huimin Feng, Sijun Wu, Wenlong Li, Zheng Li

PDF(1144 KB)
PDF(1144 KB)
Acupuncture and Herbal Medicine ›› 2022, Vol. 2 ›› Issue (1) : 9-24. DOI: 10.1097/HM9.0000000000000015
Review Article
Review Article

Granulation process analysis technologies and potential applications in traditional Chinese medicine

Author information +
History +

Abstract

Pharmaceutical production is changing from batch production to continuous production, during which granulation is one of the most important unit operations. The quality of mass-produced products is traditionally guaranteed by conducting off-line testing, which cannot meet the demand of continuous production for real-time monitoring of critical process parameters and critical quality attributes (CQAs) of the pharmaceutical granulation technology. Since the U.S. Food and Drug Administration proposed process analytical technology (PAT) in 2004, many PAT tools have been developed to monitor the granulation process and provide information regarding the granulation operation conditions and endpoint determination. In this article, we review the recent research and application of two PAT modes in the granulation process, namely, single CQA and multi-CQA PAT, with the aim to provide references for comprehensively improving the technological level of the pharmaceutical granulation process. Furthermore, the potential applications in traditional Chinese Medicine are discussed.

Keywords

Critical process parameters / Critical quality attributes / Pharmaceutical granulation technology / Process analytical technology

Cite this article

Download citation ▾
Tongcan Cui, Yizhe Hou, Huimin Feng, Sijun Wu, Wenlong Li, Zheng Li. Granulation process analysis technologies and potential applications in traditional Chinese medicine. Acupuncture and Herbal Medicine, 2022, 2(1): 9‒24 https://doi.org/10.1097/HM9.0000000000000015

References

[[1]]
Narvanen T, Lipsanen T, Antikainen O, et al. Controlling granule size by granulation liquid feed pulsing. Int J Pharm 2008; 357(1- 2):132-138.
[[2]]
Gabbott IP, Al Husban F, Reynolds GK. The combined effect of wet granulation process parameters and dried granule moisture content on tablet quality attributes. Eur J Pharm Biopharm 2016; 106(9):70-78.
[[3]]
U.S. Food and Drug Administration. Guidance for Industry. PATa framework for innovative pharmaceutical development, manufacturing and quality assurance. Silver Spring, MD: FDA; 2004. Available from: https://www.fda.gov/media/71012/down load. Accessed January 21, 2021.
[[4]]
U.S. Food and Drug Administration. Pharmaceutical cGMPs for the 21st century-a risk-based approach. September 2004. Available from: https://www.fda.gov/media/77391/download. Accessed January 20, 2021.
[[5]]
Austin J, Gupta A, Mcdonnell R, et al. The use of near-infrared and microwave resonance sensing to monitor a continuous roller compaction process. J Pharm Sci 2013; 102(6):1895-1904.
[[6]]
Gupta A, Austin J, Davis S, et al. A novel microwave sensor for real-time on-line monitoring of roll compacts of pharmaceutical powders on-line - a comparative case study with NIR. J Pharm Sci 2015; 104(5):1787-1794.
[[7]]
Lourenco V, Herdling T, Reich G, et al. Combining microwave resonance technology to multivariate data analysis as a novel PAT tool to improve process understanding in fluid bed granulation. Eur J Pharm Biopharm 2011; 78(3):513-521.
[[8]]
Zhao J, Li W, Qu H, et al. Application of definitive screening design to quantify the effects of process parameters on key granule characteristics and optimize operating parameters in pulsed-spray fluid-bed granulation. Particuology 2019; 43(2):56-65.
[[9]]
Alshihabi F, Vandamme T, Betz G. Focused beam reflectance method as an innovative (PAT) tool to monitor in-line granulation process in fluidized bed. Pharm Dev Technol 2013; 18(1):73-84.
[[10]]
Kuriyama A, Osuga J, Hattori Y, et al. In-line monitoring of a high-shear granulation process using the baseline shift of nearinfrared spectra. AAPS PharmSciTech 2018; 19(2):710-718.
[[11]]
Narang AS, Stevens T, Paruchuri S, et al. Inline focused beam reflectance measurement during wet granulation. Handbook of Pharmaceutical Wet Granulation 2019; 14(2):417-512.
[[12]]
E.L Hagrasy AS, Cruise P, Jones I, et al. In-line size monitoring of a twin screw granulation process using high-speed imaging. J Pharm Innov 2013; 8(2):90-98.
[[13]]
Kumar V, Taylor MK, Mehrotra A, et al. Real-time particle size analysis using focused beam reflectance measurement as a process analytical technology tool for a continuous granulation-dryingmilling process. AAPS Pharmscitech 2013; 14(2):523-530.
[[14]]
Shanmugam S. Granulation techniques and technologies: recent progresses. BioImpacts 2017; 5(1):55-63.
[[15]]
Teng Y, Qiu Z, Wen H. Systematical approach of formulation and process development using roller compaction. Eur J Pharm Biopharm 2009; 73(2):219-229.
[[16]]
Berkenkemper S, Keizer HL, Lindenberg M, et al. Functionality of disintegrants with different mechanisms after roll compaction. Int J Pharm 2020; 584(6):119434.
[[17]]
Vovko AD, Vrečer F. Process analytical technology tools for process control of roller compaction in solid pharmaceuticals manufacturing. Acta Pharm (Zagreb, Croatia) 2020; 70(4):443-463.
[[18]]
Kona R, Qu H, Mattes R, et al. Application of in-line nearinfrared spectroscopy and multivariate batch modeling for process monitoring in fluid bed granulation. Int J Pharm 2013; 452(1-2):63-72.
[[19]]
DA Silva CAM, Butzge JJ, Nitz M, et al. Monitoring and control of coating and granulation processes in fluidized beds - a review. Adv Powder Technol 2014; 25(1):195-210.
[[20]]
Chang E, Guo F, Yao J, et al. Application of process analytical technology in fluidized bed granulation and pellet coating process. Pharm Today 2019; 29(12):857-860.
[[21]]
Hansuld EM, Briens L. A review of monitoring methods for pharmaceutical wet granulation. Int J Pharm 2014; 472(1- 2):192-201.
[[22]]
Censi R, Gigliobianco M, Casadidio C, et al. Hot melt extrusion: highlighting physicochemical factors to be investigated while designing and optimizing a hot melt extrusion process. Pharmaceutics 2018; 10(3):89.
[[23]]
Bandari S, Nyavanandi D, Kallakunta VR, et al. Continuous twin screw granulation-an advanced alternative granulation technology for use in the pharmaceutical industry. Int J Pharm 2020; 580 (4):119215.
[[24]]
Dhenge RM, Cartwright JJ, Doughty DG, et al. Twin-screw wet granulation: effect of powder feed rate. Adv Powder Technol 2011; 22(2):162-166.
[[25]]
EL Hagrasy AS, Litster JD, et al. Granulation rate processes in the kneading elements of a twin screw granulator. AIChE J 2013; 59 (11):4100-4115.
[[26]]
EL Hagrasy AS, Hennenkamp JR, Burke MD, et al. Twin screw wet granulation: influence of formulation parameters on granule properties and growth behavior. Powder Technol 2013; 238 (4):108-115.
[[27]]
Lee KT, Ingram A, Rowson NA. Twin screw wet granulation: the study of a continuous twin screw granulator using positron emission particle tracking (PEPT) technique. Eur J Pharm Biopharm 2012; 81(3):666-673.
[[28]]
Seem TC, Rowson NA, Ingram A, et al. Twin screw granulation - a literature review. Powder Technol 2015; 276:89-102.
[[29]]
Zhong L, Gao L, Li L, et al. Trends-process analytical technology in solid oral dosage manufacturing. Eur J Pharm Biopharm 2020; 153(8):187-199.
[[30]]
Nadeem H, Heindel TJ. Review of noninvasive methods to characterize granular mixing. Powder Technol 2018; 332(6): 331-350.
[[31]]
Jang EH, Park YS, Kim MS, et al. Model based scale up methodologies for pharmaceutical granulation. Pharmaceutics 2020; 12(5):453.
[[32]]
Shekunov BY, Chattopadhyay P, Tong HHY, et al. Particle size analysis in pharmaceutics: principles, methods and applications. Pharm Res 2007; 24(2):203-227.
[[33]]
Chan LW, Tan LH, Heng PWS. Process analytical technology: application to particle sizing in spray drying. AAPS PharmSci- Tech 2008; 9(1):259-266.
[[34]]
Madarász L, Nagy ZK, Hoffer I, et al. Real-time feedback control of twin-screw wet granulation based on image analysis. Int J Pharm 2018; 547(1-2):360-367.
[[35]]
Hu X, Cunningham JC, Winstead D. Study growth kinetics in fluidized bed granulation with at-line FBRM. Int J Pharm 2008; 347(1-2):54-61.
[[36]]
Huang J, Kaul G, Utz J, et al. A PAT approach to improve process understanding of high shear wet granulation through in-line particle measurement using FBRM C35. J Pharm Sci 2010; 99 (7):3205-3212.
[[37]]
Narang AS. Resolution and sensitivity of inline focused beam reflectance measurement during wet granulation in pharmaceutically relevant particle size ranges. J Pharm Sci 2016; 105 (12):3594-3602.
[[38]]
Greaves D, Boxall J, Mulligan J, et al. Measuring the particle size of a known distribution using the focused beam reflectance measurement technique. Chem Eng Sci 2008; 63(22):5410-5419.
[[39]]
Narvanen T, Lipsanen T, Antikainen O, et al. Gaining fluid bed process understanding by in-line particle size analysis. J Pharm Sci 2009; 98(3):1110-1117.
[[40]]
Wiegel D, Eckardt G, Priese F, et al. In-line particle size measurement and agglomeration detection of pellet fluidized bed coating by spatial filter velocimetry. Powder Technol 2016; 301 (6):261-267.
[[41]]
Rossteuscher-carl K, Fricke S, Hacker MC, et al. In-line monitoring of particle size in a fluid bed granulator: investigations concerning positioning and configuration of the sensor. Int J Pharm 2014; 466(1-2):31-37.
[[42]]
Burggraeve A, Van Den Kerkhof T, Hellings M, et al. Batch statistical process control of a fluid bed granulation process using in-line spatial filter velocimetry and product temperature measurements. Eur J Pharm Sci 2011; 42(5):584-592.
[[43]]
Burggraeve A, Van Den Kerkhof T, Hellings M, et al. Evaluation of in-line spatial filter velocimetry as PAT monitoring tool for particle growth during fluid bed granulation. Eur J Pharm Biopharm 2010; 76(1):138-146.
[[44]]
Reimers T, Thies J, Stockel P, et al. Implementation of real-time and in-line feedback control for a fluid bed granulation process. Int J Pharm 2019; 567(6):118452.
[[45]]
Reimers T. Evaluation of in-line particlemeasurement with an SFTprobe as monitoring tool for process automation using a new timebased buffer approach. Eur J Pharm Sci 2019; 128(1):162-170.
[[46]]
Narvanen T, Seppala K, Antikainen O, et al. A new rapid on-line imaging method to determine particle size distribution of granules. AAPS PharmSciTech 2008; 9(1):282-287.
[[47]]
Sandler N. Photometric imaging in particle size measurement and surface visualization. Int J Pharm 2011; 417(1-2):227-234.
[[48]]
Fonteyne M, Vercruysse J, Cordoba Diaz D, et al. Real-time assessment of critical quality attributes of a continuous granulation process. Pharm Dev Technol 2013; 18(1):85-97.
[[49]]
Ismail HY, Shirazian S, Singh M, et al. Compartmental approach for modelling twin-screw granulation using population balances. Int J Pharm 2020; 576(2):118737.
[[50]]
Narang AS. Application of in-line focused beam reflectance measurement to brivanib alaninate wet granulation process to enable scale-up and attribute-based monitoring and control strategies. J Pharm Sci 2017; 106(1):224-233.
[[51]]
Yu W, Hancock BC. Evaluation of dynamic image analysis for characterizing pharmaceutical excipient particles. Int J Pharm 2008; 361(1-2):150-157.
[[52]]
Silva AFT, Burggraeve A, Denon Q, et al. Particle sizing measurements in pharmaceutical applications: comparison of in-process methods versus off-line methods. Eur J Pharm Biopharm 2013; 85(3):1006-1018.
[[53]]
Yu W, Muteki K, Zhang L, et al. Prediction of bulk powder flow performance using comprehensive particle size and particle shape distributions. J Pharm Sci 2011; 100(1):284-293.
[[54]]
Madarasz L, Nagy ZK, Hoffer I, et al. Real-time feedback control of twin-screw wet granulation based on image analysis. Int J Pharm 2018; 547(1-2):360-367.
[[55]]
Wilms A, Knop K, Kleinebudde P. Combination of a rotating tube sample divider and dynamic image analysis for continuous on-line determination of granule size distribution. Int J Pharm 2019; 12 (1):100029.
[[56]]
McauliffeF MaP, O’mahony GE, Blackshields CA, et al. The use of PAT and off-line methods for monitoring of roller compacted ribbon and granule properties with a view to continuous processing. Org Process Res Dev 2015; 19(1):158-166.
[[57]]
Kumar A, Dhondt J, De Leersnyder F, et al. Evaluation of an inline particle imaging tool for monitoring twin-screw granulation performance. Powder Technol 2015; 285(5):80-87.
[[58]]
Sayin R, Martinez-marcos L, Osorio JG, et al. Investigation of an 11mm diameter twin screw granulator: screw element performance and in-line monitoring via image analysis. Int J Pharm 2015; 496(1):24-32.
[[59]]
Fonteyne M, Soares S, Vercruysse J, et al. Prediction of quality attributes of continuously produced granules using complementary PAT tools. Eur J Pharm Biopharm 2012; 82(2):429-436.
[[60]]
Wilms A, Meier R, Kleinebudde P. Development and evaluation of an in-line and on-line monitoring system for granule size distributions in continuous roll compaction/dry granulation based on laser diffraction. J Pharm Innov 2021; 16(2):247-257.
[[61]]
Madarasz L, Kote A, Gyurkes M, et al. Videometric mass flow control: a new method for real-time measurement and feedback control of powder micro-feeding based on image analysis. Int J Pharm 2020; 580(4):119223.
[[62]]
Beer TD. Near-infrared and Raman spectroscopy for the inprocess monitoring of pharmaceutical production processes. Int J Pharm 2011;16.
[[63]]
Liu R. Near-infrared spectroscopy monitoring and control of the fluidized bed granulation and coating processes - a review. Int J Pharm 2020; 417(1-2):32-47.
[[64]]
Razuc M, Grafia A, Gallo L, et al. Near-infrared spectroscopic applications in pharmaceutical particle technology. Drug Dev Ind Pharm 2019; 45(10):1565-1589.
[[65]]
Pauli V, Roggo Y, Kleinebudde P, et al. Real-time monitoring of particle size distribution in a continuous granulation and drying process by near-infrared spectroscopy. Eur J Pharm Biopharm 2019; 141(8):90-99.
[[66]]
Shibayama S, Funatsu K. Investigation of preprocessing and validation methodologies for PAT: case study of the granulation and coating steps for the manufacturing of ethenzamide tablets. AAPS PharmSciTech 2021; 22(1):41.
[[67]]
Crowley ME, Hegarty A, Mcauliffe MAP, et al. Near-infrared monitoring of roller compacted ribbon density: investigating sources of variation contributing to noisy spectral data. Eur J Pharm Sci 2017; 102(5):103-114.
[[68]]
Gupta A, Peck GE, Miller RW, et al. Nondestructive measurements of the compact strength and the particle-size distribution after milling of roller compacted powders by near-infrared spectroscopy. J Pharm Sci 2004; 93(4):1047-1053.
[[69]]
Martinetz MC, Karttunen A-P, Sacher S, et al. RTD-based material tracking in a fully continuous dry granulation tableting line. Int J Pharm 2018; 547(1-2):469-479.
[[70]]
Gavan A, Iurian S, Casian T, et al. Fluidised bed granulation of two APIs: QbD approach and development of a NIR in-line monitoring method. Asian J Pharm Sci 2020; 15(4):506-517.
[[71]]
Chablani L, Taylor MK, Mehrotra A, et al. Inline real-time nearinfrared granule moisture measurements of a continuous granulation-drying-milling process. AAPS PharmSciTech 2011; 12(4):1050-1055.
[[72]]
Tian G, Wei Y, Zhao J, et al. Application of pulsed spray and moisture content control strategies on quality consistency control in fluidized bed granulation: a comparative study. Powder Technol 2020; 363(3):232-244.
[[73]]
Tian G, Wei Y, Zhao J, et al. Application of near-infrared spectroscopy combined with design of experiments for process development of the pulsed spray fluid bed granulation process. Powder Technol 2018; 339:521-533.
[[74]]
Zhao J, Li W, Qu H, et al. Real-time monitoring and fault detection of pulsed-spray fluid-bed granulation using nearinfrared spectroscopy and multivariate process trajectories. Particuology 2020; 53(12):112-123.
[[75]]
De Oliveira RR, Avila C, Bourne R, et al. Data fusion strategies to combine sensor and multivariate model outputs for multivariate statistical process control. Anal Bioanal Chem 2020; 412 (9):2151-2163.
[[76]]
Román-Ospino AD, Tamrakar A, Igne B, et al. Characterization of NIR interfaces for the feeding and in-line monitoring of a continuous granulation process. Int J Pharm 2020; 574(12): 118848.
[[77]]
Avila CR, Ferré J, De Oliveira RR, et al. Process monitoring of moisture content and mass transfer rate in a fluidised bed with a low cost inline MEMS NIR sensor. Pharm Res 2020; 37 (5):1-19.
[[78]]
Roggo Y, Pauli V, Jelsch M, et al. Continuous manufacturing process monitoring of pharmaceutical solid dosage form: a case study. J Pharm Biomed Anal 2020; 179(2):112971.
[[79]]
Roggo Y, Jelsch M, Heger P, et al. Deep learning for continuous manufacturing of pharmaceutical solid dosage form. Eur J Pharm Biopharm 2020; 153(8):95-105.
[[80]]
Meng W, Roman-ospino AD, Panikar SS, et al. Advanced process design and understanding of continuous twin-screw granulation via implementation of in-line process analytical technologies. Adv Powder Technol 2019; 30(4):879-894.
[[81]]
Alcalà M, Blanco M, Bautista M, et al. On-line monitoring of a granulation process by NIR spectroscopy. J Pharm Sci 2010; 99 (1):336-345.
[[82]]
Nagy B, Farkas A, Borbas E, et al. Raman spectroscopy for process analytical technologies of pharmaceutical secondary manufacturing. AAPS Pharmscitech 2019; 20(1):1-16.
[[83]]
Harting J, Kleinebudde P. Development of an in-line Raman spectroscopic method for continuous API quantification during twin-screw wet granulation. Eur J Pharm Biopharm 2018; 125 (2):169-181.
[[84]]
Hausman DS, Cambron RT, Sakr A. Application of on-line Raman spectroscopy for characterizing relationships between drug hydration state and tablet physical stability. Int J Pharm 2005; 299(1-2):19-33.
[[85]]
Bhavana V, Chavan RB, Mannava MKC, et al. Quantification of niclosamide polymorphic forms-a comparative study by Raman, NIR and MIR using chemometric techniques. Talanta 2019; 199 (3):679-688.
[[86]]
Harting J, Kleinebudde P. Optimisation of an in-line Raman spectroscopic method for continuous API quantification during twin-screw wet granulation and its application for process characterisation. Eur J Pharm Biopharm 2019; 137(4):77-85.
[[87]]
Reddy JP, Jones JW, Wray PS, et al. Monitoring of multiple solvent induced form changes during high shear wet granulation and drying processes using on-line Raman spectroscopy. Int J Pharm 2018; 541(1-2):253-260.
[[88]]
Otaki T, Tanabe Y, Kojima T, et al. In situ monitoring of cocrystals in formulation development using low-frequency Raman spectroscopy. Int J Pharm 2018; 542(1-2):56-65.
[[89]]
Nomura K, Titapiwatanakun V, Hisada H, et al. In situ monitoring of the crystalline state of active pharmaceutical ingredients during high-shear wet granulation using a lowfrequency Raman probe. Eur J Pharm Biopharm 2020; 147(2): 1-9.
[[90]]
Hisazumi J, Kleinebudde P. In-line monitoring of multi-layered film-coating on pellets using Raman spectroscopy by MCR and PLS analyses. Eur J Pharm Biopharm 2017; 114(5):194-201.
[[91]]
Brouckaert D, De Meyer L, Vanbillemont B, et al. Potential of near-infrared chemical imaging as process analytical technology tool for continuous freeze-drying. Anal Chem 2018; 90(7):4354-4362.
[[92]]
Zhou L, Xu M, Wu Z, et al. PAT: from Western solid dosage forms to Chinese materia medica preparations using NIR-CI. Drug Test Anal 2016; 8(1):72-86.
[[93]]
Yu M, Omar C, Weidemann M, et al. Roller compaction: infrared thermography as a PAT for monitoring powder flow from feeding to compaction zone. Int J Pharm 2020; 578(3):119114.
[[94]]
Wiedey R, Kleinebudde P. Potentials and limitations of thermography as an in-line tool for determining ribbon solid fraction. Powder Technol 2019; 341(1):2-10.
[[95]]
Wiedey R, Kleinebudde P. Infrared thermography-a new approach for in-line density measurement of ribbons produced from roll compaction. Powder Technol 2018; 337:17-24.
[[96]]
Wiedey R, Sibanc R, Wilms A, et al. How relevant is ribbon homogeneity in roll compaction/dry granulation and can it be influenced? Eur J Pharm Biopharm 2018; 133(12):232-239.
[[97]]
Zeitler JA, Shen Y, Baker C, et al. Analysis of coating structures and interfaces in solid oral dosage forms by three dimensional terahertz pulsed imaging. J Pharm Sci 2007; 96(2):330-340.
[[98]]
Zhang J, Pei C, Schiano S, et al. The application of terahertz pulsed imaging in characterising density distribution of rollcompacted ribbons. Eur J Pharm Biopharm 2016; 106(9):20-25.
[[99]]
Wesholowski J, Berghaus A, Thommes M. Inline determination of residence time distribution in hot-melt-extrusion. Pharmaceutics 2018; 10(2):49.
[[100]]
Tsujimoto H, Yokoyama T, Huang CC, et al. Monitoring particle fluidization in a fluidized bed granulator with an acoustic emission sensor. Powder Technol 2000; 113(1-2):88-96.
[[101]]
Poutiainen S, Matero S, Hämäläinen T, et al. Predicting granule size distribution of a fluidized bed spray granulation process by regime based PLS modeling of acoustic emission data. Powder Technol 2012; 228(9):149-157.
[[102]]
Hansuld EM, Briens L, Sayani A, et al. Monitoring quality attributes for high-shear wet granulation with audible acoustic emissions. Powder Technol 2012; 215-216(1):117-123.
[[103]]
Sheahan T, Briens L. Passive acoustic emissions monitoring of the coating of pellets in a fluidized bed-a feasibility analysis. Powder Technol 2015; 283(10):373-379.
[[104]]
Watson NJ, Povey MJW, Reynolds GK, et al. Acoustic emission monitoring from a lab scale high shear granulator-a novel approach. Int J Pharm 2014; 465(1-2):262-274.
[[105]]
Rantanen J, Wikstrom H, Turner R, et al. Use of in-line nearinfrared spectroscopy in combination with chemometrics for improved understanding of pharmaceutical processes. Anal Chem 2005; 77(2):556-563.
[[106]]
Peters J, Bartscher K, Doescher C, et al. In-line moisture monitoring in fluidized bed granulation using a novel multiresonance microwave sensor. Talanta 2017; 170(4):369-376.
[[107]]
Peters J, Taute W, Doscher C, et al. From laboratory to pilot scale: moisture monitoring in fluidized bed granulation by a novel microwave sensor using multivariate calibration approaches. Drug Develop Indus Pharm 2018; 44(6):961-968.
[[108]]
Peters J, Taute W, Döscher C, et al. Moisture monitoring in fluidbed granulation by multi-resonance microwave sensor: applicability on crystal-water containing donepezil granules. AAPS PharmSciTech 2019; 20(1):1-9.
[[109]]
Peters J, Taute W, Bartscher K, et al. Design, development and method validation of a novelmulti-resonancemicrowave sensor for moisture measurement. Anal Chim Acta 2017; 961(4):119-127.
[[110]]
Peters J, Teske A, Taute W, et al. Real-time process monitoring in a semi-continuous fluid-bed dryer-microwave resonance technology versus near-infrared spectroscopy. Int J Pharm 2018; 537(1- 2):193-201.
[[111]]
Rimpilainen V, Heikkinen LM, Vauhkonen M. Moisture distribution and hydrodynamics of wet granules during fluidized bed drying characterized with volumetric electrical capacitance tomography. Chem Eng Sci 2012; 75(6):220-234.
[[112]]
Che HQ, Ye JM, Tu QY, et al. Investigation of coating process in Wurster fluidised bed using electrical capacitance tomography. Chem Eng Res Design 2018; 132(2):1180-1192.
[[113]]
Ghorab MK, Chatlapalli R, Hasan S, et al. Application of thermal effusivity as a process analytical technology tool for monitoring and control of the roller compaction process. AAPS PharmSci- Tech 2007; 8(1):E155-E161.
[[114]]
Narang AS, Sheverev VA, Stepaniuk V, et al. Real-time assessment of granule densification in high shear wet granulation and application to scale-up of a placebo and a brivanib alaninate formulation. J Pharm Sci 2015; 104(3):1019-1034.
[[115]]
Narang AS, Sheverev V, Freeman T, et al. Process analytical technology for high shear wet granulation: wet mass consistency reported by in-line drag flow force sensor is consistent with powder rheology measured by at-line ft 4 powder rheometer®. J Pharm Sci 2016; 105(1):182-187.
[[116]]
Ba Y, Xu LL, Nian H, et al. Review on granulation technology of traditional Chinese medicine granules. Chin Pharmacist 2010; 13 (5):733-736.
[[117]]
Gong A, Chen GH. Application of fluidized bed in the production of traditional Chinese medicine. J Chin Med Mater 2007; (10):1329-1332.
[[118]]
Wu SQ, Wu ZF, Yang M, et al. Research overview of granulation technology and equipment of traditional Chinese medicine. Chin J Pharm 2016; 47(3):341-346.
[[119]]
Li GR, Hou HF, Huang JJ, et al. Study on the preparation method of compound Shuangshen granules. Ginseng Res 2019; 31(4):5-7.
[[120]]
Optimization of dry granulation prescription and technology of anti-Hashimoto’s thyroiditis formula granules based on physical characteristics of raw materials in preparations. Chin Tradit Herb Drugs 2018; 49(3):575-581.
[[121]]
Dong DY, Zang S, Pan HJ, et al. Application of dry granulation technology in granulation process of extract powder from Chinese traditional medicine. Chin J Exp Tradit Med Formul 2012; 18(14):306-309.
[[122]]
Application of dry granulation technology in preparation of oral solid preparation of traditional Chinese medicine. Mod Chin Med 2020; 22(5):827-834.
[[123]]
Yang XJ, Chen L. Application of numerical simulation to tablet formation. Chin J Pharm 2012; 43(9):790-795.
[[124]]
Wang F, Xu B, Qiao YJ, et al. Chinese medicine quality derived from design methods and applications for-(VI): continuous manufacturing. World Chin Med 2018; 13(3):566-573.
[[125]]
Yu JQ, Xu B, Qiao YJ, et al. Chinese medicine quality derived from design methods and applications for-(VII): intelligent manufacturing. World Chin Med 2018; 13(3):574-579.
[[126]]
Hu YJ, Wang G, Yi C, et al. Optimization of dry granulation formulation and process of andrographis herba granules by L18- hunter design based on critical quality attributes. J Chin Med Mater 2017; 40(12):2908-2912.
[[127]]
Kuang WW, Wu ZF, Yang M, et al. Discussion on research thought of dry granulation of traditional Chinese medicine: research progress at home and abroad based on dry granulation technology. China J Chin Mater Media 2019; 44(15):3195-3202.
[[128]]
Liu X, Chen J, Chen GQ, et al. On-line detection of concentration process of Ganmaoling granules by near infrared spectroscopy combined with automatic control system. Acta Pharm Sin 2017; 52(3):462-467.
[[129]]
Wang ZC, Yuan XJ, Wang P, et al. Analysis of acoustic emissions and measurement of particle sizes in cyclone. Chem Eng (China) 2016; 44(12):70-74.
[[130]]
Zhang CY, Li XX, Li HJ, et al. Consistency evaluation between dispensing granule and traditional decoction from Coptidis Rhizoma by using an integrated quality-based strategy. Phytochem Anal 2021; 32(2):153-164.
[[131]]
Zhou JL. Review and prospect of the progress of Chinese medicine formula granules. Mod Chin Med 2016; 18(9):1093-1096.
[[132]]
Zeng YH, Xiao J, Yang XF, et al. Discussion on the reform of dosage form of traditional Chinese medicine. J Tradit Chin Med Manag 2020; 28(2):225-226.
[[133]]
Zhang K, Zhong XM. Research progress on forming technology of traditional Chinese medicine granules. Strait Pharm 2010; 22 (1):27-28.
[[134]]
Research progress in preparation technology of Chinese medicine granules. Inner Mongol Tradit Chin Med 2018; 37(5):103-105.
[[135]]
Li HC, Deng XM, Peng XP, et al. Analysis of the present situation of research on standardization of traditional Chinese medicine formula granules. Chin J Inform Tradit Chin Med 2017; 24 (7):11-14.
[[136]]
Jin Z, Andong Y, Wei Z, et al. Research status of key technologies and intelligent manufacturing equipment for quality assurance of traditional Chinese medicine formula granules. Pharmacol Clin Tradit Chin Med 2021;1-16.
PDF(1144 KB)

Accesses

Citations

Detail

Sections
Recommended

/