Advances in Catheter Ablation of Ventricular Tachycardia: Technical Considerations and Contemporary Approaches
Corrado De Marco , Alexios Hadjis , Wouter Saint-Phard , Jean-Marc Raymond
Reviews in Cardiovascular Medicine ›› 2026, Vol. 27 ›› Issue (8) : 52698
Ventricular tachycardia (VT) is a life-threatening arrhythmia that most commonly arises from reentrant circuits within myocardial scar in patients with structural heart disease. Although implantable cardioverter-defibrillators (ICDs) reduce sudden cardiac death, these devices do not prevent VT and are associated with significant physical and psychological burdens, while antiarrhythmic drug therapy is often limited by incomplete efficacy and adverse effects. These limitations have driven the increasing use of catheter ablation to target arrhythmogenic substrates. This review examines the evolving role of catheter ablation in VT management, including the supporting evidence, patient selection, procedural timing, and contemporary mapping and ablation strategies, drawing on data from randomized clinical trials, observational studies, and recent technological advances. Multiple trials, including SMASH-VT, VTACH, VANISH, SURVIVE-VT, and VANISH-2, have shown that catheter ablation reduces VT recurrence and ICD therapies, with growing evidence supporting the earlier or even first-line use of this technique in selected patients. Substrate-based ablation has become the cornerstone of modern practice, enabling effective treatment during sinus rhythm; meanwhile, preprocedural imaging, such as cardiac magnetic resonance and computed tomography, enhances scar characterization and procedural planning. Advanced approaches, including epicardial ablation, bipolar and needle ablation, and alternative energy delivery techniques, help overcome the limitations of conventional endocardial radiofrequency lesions. Emerging modalities, such as pulsed field ablation, show promise but require further validation. Despite these advances, VT-free survival remains approximately 50–60%, reflecting the complexity of the underlying arrhythmogenic substrates. Overall, catheter ablation has become an integral component of contemporary VT management, offering meaningful reductions in arrhythmia burden and ICD therapies, with increasing use earlier in the disease course; meanwhile, ongoing innovations in mapping, imaging integration, and energy delivery are expected to improve outcomes further, pending continued investigation into optimal patient selection, procedural timing, and long-term efficacy.
ventricular tachycardia / catheter ablation / antiarrhythmic drugs / implantable cardioverter defibrillator / sudden cardiac death
| [1] |
Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators. A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias[J]. The New England Journal of Medicine, 1997, 337: 1576-1583. DOI: 10.1056/NEJM199711273372202. |
| [2] |
CONNOLLY SJ, GENT M, ROBERTS RS, et al. Canadian implantable defibrillator study (CIDS): a randomized trial of the implantable cardioverter defibrillator against amiodarone[J]. Circulation, 2000, 101: 1297-1302. DOI: 10.1161/01.cir.101.11.1297. |
| [3] |
BILGE AK, OZBEN B, DEMIRCAN S, et al. Depression and anxiety status of patients with implantable cardioverter defibrillator and precipitating factors[J]. Pacing and Clinical Electrophysiology: PACE, 2006, 29: 619-626. DOI: 10.1111/j.1540-8159.2006.00409.x. |
| [4] |
KAMPHUIS HCM, DE LEEUW JRJ, DERKSEN R, et al. Implantable cardioverter defibrillator recipients: quality of life in recipients with and without ICD shock delivery: a prospective study[J]. Europace: European Pacing, Arrhythmias, and Cardiac Electrophysiology: Journal of the Working Groups on Cardiac Pacing, Arrhythmias, and Cardiac Cellular Electrophysiology of the European Society of Cardiology, 2003, 5: 381-389. DOI: 10.1016/s1099-5129(03)00078-3. |
| [5] |
BENNETT MT, BROWN ML, KOEHLER J, et al. Trends in implantable cardioverter-defibrillator programming practices and its impact on therapies: Insights from a North American Remote Monitoring Registry 2007-2018[J]. Heart Rhythm, 2022, 19: 219-225. DOI: 10.1016/j.hrthm.2021.10.010. |
| [6] |
PERINI AP, KUTYIFA V, VEAZIE P, et al. Effects of implantable cardioverter/defibrillator shock and antitachycardia pacing on anxiety and quality of life: A MADIT-RIT substudy[J]. American Heart Journal, 2017, 189: 75-84. DOI: 10.1016/j.ahj.2017.03.009. |
| [7] |
ELSOKKARI I, PARKASH R, TANG A, et al. Mortality Risk Increases With Clustered Ventricular Arrhythmias in Patients With Implantable Cardioverter-Defibrillators[J]. JACC. Clinical Electrophysiology, 2020, 6: 327-337. DOI: 10.1016/j.jacep.2019.11.012. |
| [8] |
AL-KHATIB SM, STEVENSON WG, ACKERMAN MJ, et al. 2017 AHA/ACC/HRS Guideline for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society[J]. Circulation, 2018, 138: e272-e391. DOI: 10.1161/CIR.0000000000000549. |
| [9] |
BOKHARI F, NEWMAN D, GREENE M, et al. Long-term comparison of the implantable cardioverter defibrillator versus amiodarone: eleven-year follow-up of a subset of patients in the Canadian Implantable Defibrillator Study (CIDS)[J]. Circulation, 2004, 110: 112-116. DOI: 10.1161/01.CIR.0000134957.51747.6E. |
| [10] |
SAPP JL, WELLS GA, PARKASH R, et al. Ventricular Tachycardia Ablation versus Escalation of Antiarrhythmic Drugs[J]. The New England Journal of Medicine, 2016, 375: 111-121. DOI: 10.1056/NEJMoa1513614. |
| [11] |
SAPP JL, TANG ASL, PARKASH R, et al. Catheter Ablation or Antiarrhythmic Drugs for Ventricular Tachycardia[J]. The New England Journal of Medicine, 2025, 392: 737-747. DOI: 10.1056/NEJMoa2409501. |
| [12] |
MILLER JM, MARCHLINSKI FE, HARKEN AH, et al. Subendocardial resection for sustained ventricular tachycardia in the early period after acute myocardial infarction[J]. The American Journal of Cardiology, 1985, 55: 980-984. DOI: 10.1016/0002-9149(85)90730-1. |
| [13] |
HARTZLER GO. Electrode catheter ablation of refractory focal ventricular tachycardia[J]. Journal of the American College of Cardiology, 1983, 2: 1107-1113. DOI: 10.1016/s0735-1097(83)80337-4. |
| [14] |
STEVENSON WG, KHAN H, SAGER P, et al. Identification of reentry circuit sites during catheter mapping and radiofrequency ablation of ventricular tachycardia late after myocardial infarction[J]. Circulation, 1993, 88: 1647-1670. DOI: 10.1161/01.cir.88.4.1647. |
| [15] |
BHASKARAN A, NAYYAR S, PORTA-SÁNCHEZ A, et al. Exit sites on the epicardium rarely subtend critical diastolic path of ischemic VT on the endocardium: Implications for noninvasive ablation[J]. Journal of Cardiovascular Electrophysiology, 2019, 30: 520-527. DOI: 10.1111/jce.13843. |
| [16] |
HSIA HH, CALLANS DJ, MARCHLINSKI FE. Characterization of endocardial electrophysiological substrate in patients with nonischemic cardiomyopathy and monomorphic ventricular tachycardia[J]. Circulation, 2003, 108: 704-710. DOI: 10.1161/01.CIR.0000083725.72693.EA. |
| [17] |
REDDY VY, REYNOLDS MR, NEUZIL P, et al. Prophylactic catheter ablation for the prevention of defibrillator therapy[J]. The New England Journal of Medicine, 2007, 357: 2657-2665. DOI: 10.1056/NEJMoa065457. |
| [18] |
STEVENSON WG, WILBER DJ, NATALE A, et al. Irrigated radiofrequency catheter ablation guided by electroanatomic mapping for recurrent ventricular tachycardia after myocardial infarction: the multicenter thermocool ventricular tachycardia ablation trial[J]. Circulation, 2008, 118: 2773-2782. DOI: 10.1161/CIRCULATIONAHA.108.788604. |
| [19] |
MIZUNO H, VERGARA P, MACCABELLI G, et al. Contact force monitoring for cardiac mapping in patients with ventricular tachycardia[J]. Journal of Cardiovascular Electrophysiology, 2013, 24: 519-524. DOI: 10.1111/jce.12080. |
| [20] |
KUCK KH, SCHAUMANN A, ECKARDT L, et al. Catheter ablation of stable ventricular tachycardia before defibrillator implantation in patients with coronary heart disease (VTACH): a multicentre randomised controlled trial[J]. Lancet (London, England), 2010, 375: 31-40. DOI: 10.1016/S0140-6736(09)61755-4. |
| [21] |
KUCK KH, TILZ RR, DENEKE T, et al. Impact of Substrate Modification by Catheter Ablation on Implantable Cardioverter-Defibrillator Interventions in Patients With Unstable Ventricular Arrhythmias and Coronary Artery Disease: Results From the Multicenter Randomized Controlled SMS (Substrate Modification Study)[J]. Circulation. Arrhythmia and Electrophysiology, 2017, 10: e004422. DOI: 10.1161/CIRCEP.116.004422. |
| [22] |
TUNG R, XUE Y, CHEN M, et al. First-Line Catheter Ablation of Monomorphic Ventricular Tachycardia in Cardiomyopathy Concurrent With Defibrillator Implantation: The PAUSE-SCD Randomized Trial[J]. Circulation, 2022, 145: 1839-1849. DOI: 10.1161/CIRCULATIONAHA.122.060039. |
| [23] |
WILLEMS S, TILZ RR, STEVEN D, et al. Preventive or Deferred Ablation of Ventricular Tachycardia in Patients With Ischemic Cardiomyopathy and Implantable Defibrillator (BERLIN VT): A Multicenter Randomized Trial[J]. Circulation, 2020, 141: 1057-1067. DOI: 10.1161/CIRCULATIONAHA.119.043400. |
| [24] |
DELLA BELLA P, BARATTO F, VERGARA P, et al. Does Timing of Ventricular Tachycardia Ablation Affect Prognosis in Patients With an Implantable Cardioverter Defibrillator? Results From the Multicenter Randomized PARTITA Trial[J]. Circulation, 2022, 145: 1829-1838. DOI: 10.1161/CIRCULATIONAHA.122.059598. |
| [25] |
ARENAL Á, ÁVILA P, JIMÉNEZ-CANDIL J, et al. Substrate Ablation vs Antiarrhythmic Drug Therapy for Symptomatic Ventricular Tachycardia[J]. Journal of the American College of Cardiology, 2022, 79: 1441-1453. DOI: 10.1016/j.jacc.2022.01.050. |
| [26] |
BURGER JC, HOPMAN LHGA, KEMME MJB, et al. Optimizing ventricular tachycardia ablation through imaging-based assessment of arrhythmic substrate: A comprehensive review and roadmap for the future[J]. Heart Rhythm O2, 2024, 5: 561-572. DOI: 10.1016/j.hroo.2024.07.001. |
| [27] |
VÁZQUEZ-CALVO S, MAS CASANOVAS J, GARRE P, et al. Non-invasive detection of slow conduction with cardiac magnetic resonance imaging for ventricular tachycardia ablation[J]. Europace: European Pacing, Arrhythmias, and Cardiac Electrophysiology: Journal of the Working Groups on Cardiac Pacing, Arrhythmias, and Cardiac Cellular Electrophysiology of the European Society of Cardiology, 2024, 26: euae025. DOI: 10.1093/europace/euae025. |
| [28] |
ANDREU D, PENELA D, ACOSTA J, et al. Cardiac magnetic resonance-aided scar dechanneling: Influence on acute and long-term outcomes[J]. Heart Rhythm, 2017, 14: 1121-1128. DOI: 10.1016/j.hrthm.2017.05.018. |
| [29] |
PENELA D, FALASCONI G, SOTO-IGLESIAS D, et al. Outcomes of ventricular tachycardia ablation facilitated by pre-procedural cardiac imaging-derived scar characterization: a prospective multi-centre international registry[J]. Europace: European Pacing, Arrhythmias, and Cardiac Electrophysiology: Journal of the Working Groups on Cardiac Pacing, Arrhythmias, and Cardiac Cellular Electrophysiology of the European Society of Cardiology, 2025, 27: euaf051. DOI: 10.1093/europace/euaf051. |
| [30] |
MUSER D, CASTRO SA, LIANG JJ, et al. Identifying Risk and Management of Acute Haemodynamic Decompensation During Catheter Ablation of Ventricular Tachycardia[J]. Arrhythmia & Electrophysiology Review, 2018, 7: 282-287. DOI: 10.15420/aer.2018.36.3. |
| [31] |
JOHN LA, JOHN II, TEDFORD RJ, et al. Substrate Imaging Before Catheter Ablation of Ventricular Tachycardia: Risk Prediction for Acute Hemodynamic Decompensation[J]. JACC. Clinical Electrophysiology, 2023, 9: 1684-1693. DOI: 10.1016/j.jacep.2023.03.023. |
| [32] |
MATHURIA N, WU G, ROJAS-DELGADO F, et al. Outcomes of pre-emptive and rescue use of percutaneous left ventricular assist device in patients with structural heart disease undergoing catheter ablation of ventricular tachycardia[J]. Journal of Interventional Cardiac Electrophysiology: an International Journal of Arrhythmias and Pacing, 2017, 48: 27-34. DOI: 10.1007/s10840-016-0168-8. |
| [33] |
SANTANGELI P, FRANKEL DS, TUNG R, et al. Early Mortality After Catheter Ablation of Ventricular Tachycardia in Patients With Structural Heart Disease[J]. Journal of the American College of Cardiology, 2017, 69: 2105-2115. DOI: 10.1016/j.jacc.2017.02.044. |
| [34] |
MUSER D, LIANG JJ, CASTRO SA, et al. Outcomes with prophylactic use of percutaneous left ventricular assist devices in high-risk patients undergoing catheter ablation of scar-related ventricular tachycardia: A propensity-score matched analysis[J]. Heart Rhythm, 2018, 15: 1500-1506. DOI: 10.1016/j.hrthm.2018.04.028. |
| [35] |
JAÏS P, MAURY P, KHAIRY P, et al. Elimination of local abnormal ventricular activities: a new end point for substrate modification in patients with scar-related ventricular tachycardia[J]. Circulation, 2012, 125: 2184-2196. DOI: 10.1161/CIRCULATIONAHA.111.043216. |
| [36] |
DI BIASE L, BURKHARDT JD, LAKKIREDDY D, et al. Ablation of Stable VTs Versus Substrate Ablation in Ischemic Cardiomyopathy: The VISTA Randomized Multicenter Trial[J]. Journal of the American College of Cardiology, 2015, 66: 2872-2882. DOI: 10.1016/j.jacc.2015.10.026. |
| [37] |
DI BIASE L, SANTANGELI P, BURKHARDT DJ, et al. Endo-epicardial homogenization of the scar versus limited substrate ablation for the treatment of electrical storms in patients with ischemic cardiomyopathy[J]. Journal of the American College of Cardiology, 2012, 60: 132-141. DOI: 10.1016/j.jacc.2012.03.044. |
| [38] |
KATRITSIS G, KAILEY B, JAMIL-COPLEY S, et al. RIPPLE-VT study: Multicenter prospective evaluation of ventricular tachycardia substrate ablation by targeting scar channels to eliminate latest scar potentials without direct ablation[J]. Heart Rhythm, 2024, 21: 2481-2490. DOI: 10.1016/j.hrthm.2024.05.046. |
| [39] |
ANTER E, TSCHABRUNN CM, BUXTON AE, et al. High-Resolution Mapping of Postinfarction Reentrant Ventricular Tachycardia: Electrophysiological Characterization of the Circuit[J]. Circulation, 2016, 134: 314-327. DOI: 10.1161/CIRCULATIONAHA.116.021955. |
| [40] |
AZIZ Z, SHATZ D, RAIMAN M, et al. Targeted Ablation of Ventricular Tachycardia Guided by Wavefront Discontinuities During Sinus Rhythm: A New Functional Substrate Mapping Strategy[J]. Circulation, 2019, 140: 1383-1397. DOI: 10.1161/CIRCULATIONAHA.119.042423. |
| [41] |
PORTA-SÁNCHEZ A, JACKSON N, LUKAC P, et al. Multicenter Study of Ischemic Ventricular Tachycardia Ablation With Decrement-Evoked Potential (DEEP) Mapping With Extra Stimulus[J]. JACC. Clinical Electrophysiology, 2018, 4: 307-315. DOI: 10.1016/j.jacep.2017.12.005. |
| [42] |
DE RIVA M, EVERTZ R, LUKAC P, et al. Evoked delayed potential ablation for post-myocardial infarction ventricular tachycardia: results from a large prospective multicentre study[J]. Europace: European Pacing, Arrhythmias, and Cardiac Electrophysiology: Journal of the Working Groups on Cardiac Pacing, Arrhythmias, and Cardiac Cellular Electrophysiology of the European Society of Cardiology, 2025, 27: euaf003. DOI: 10.1093/europace/euaf003. |
| [43] |
GUICHARD JB, REGANY-CLOSA M, VÁZQUEZ-CALVO S, et al. Substrate Mapping for Ventricular Tachycardia Ablation Through High-Density Whole-Chamber Double Extra Stimuli: The S3 Protocol[J]. JACC. Clinical Electrophysiology, 2024, 10: 1534-1547. DOI: 10.1016/j.jacep.2024.04.023. |
| [44] |
REDDY VY, WROBLESKI D, HOUGHTALING C, et al. Combined epicardial and endocardial electroanatomic mapping in a porcine model of healed myocardial infarction[J]. Circulation, 2003, 107: 3236-3242. DOI: 10.1161/01.CIR.0000074280.62478.E1. |
| [45] |
TUNG R, KIM S, YAGISHITA D, et al. Scar voltage threshold determination using ex vivo magnetic resonance imaging integration in a porcine infarct model: Influence of interelectrode distances and three-dimensional spatial effects of scar[J]. Heart Rhythm, 2016, 13: 1993-2002. DOI: 10.1016/j.hrthm.2016.07.003. |
| [46] |
HUTCHINSON MD, GERSTENFELD EP, DESJARDINS B, et al. Endocardial unipolar voltage mapping to detect epicardial ventricular tachycardia substrate in patients with nonischemic left ventricular cardiomyopathy[J]. Circulation: Arrhythmia and electrophysiology, 2011, 4: 49-55. DOI: 10.1161/CIRCEP.110.959957. |
| [47] |
BRUNCKHORST CB, DELACRETAZ E, SOEJIMA K, et al. Identification of the ventricular tachycardia isthmus after infarction by pace mapping[J]. Circulation, 2004, 110: 652-659. DOI: 10.1161/01.CIR.0000138107.11518.AF. |
| [48] |
SILBERBAUER J, OLORIZ T, MACCABELLI G, et al. Noninducibility and late potential abolition: a novel combined prognostic procedural end point for catheter ablation of postinfarction ventricular tachycardia[J]. Circulation. Arrhythmia and Electrophysiology, 2014, 7: 424-435. DOI: 10.1161/CIRCEP.113.001239. |
| [49] |
MAHER TR, FREEDMAN BL, YANG S, et al. Targeting Wavefront Discontinuity Lines for Scar-Related Ventricular Tachycardia Ablation: A Novel Functional Substrate Ablation Approach[J]. JACC. Clinical Electrophysiology, 2024, 10: 1255-1270. DOI: 10.1016/j.jacep.2024.03.023. |
| [50] |
IRIE T, YU R, BRADFIELD JS, et al. Relationship between sinus rhythm late activation zones and critical sites for scar-related ventricular tachycardia: systematic analysis of isochronal late activation mapping[J]. Circulation. Arrhythmia and Electrophysiology, 2015, 8: 390-399. DOI: 10.1161/CIRCEP.114.002637. |
| [51] |
HADJIS A, FRONTERA A, LIMITE LR, et al. Complete Electroanatomic Imaging of the Diastolic Pathway Is Associated With Improved Freedom From Ventricular Tachycardia Recurrence[J]. Circulation. Arrhythmia and Electrophysiology, 2020, 13: e008651. DOI: 10.1161/CIRCEP.120.008651. |
| [52] |
MARCHLINSKI FE, HAFFAJEE CI, BESHAI JF, et al. Long-Term Success of Irrigated Radiofrequency Catheter Ablation of Sustained Ventricular Tachycardia: Post-Approval THERMOCOOL VT Trial[J]. Journal of the American College of Cardiology, 2016, 67: 674-683. DOI: 10.1016/j.jacc.2015.11.041. |
| [53] |
TANNER H, HINDRICKS G, VOLKMER M, et al. Catheter ablation of recurrent scar-related ventricular tachycardia using electroanatomical mapping and irrigated ablation technology: results of the prospective multicenter Euro-VT-study[J]. Journal of Cardiovascular Electrophysiology, 2010, 21: 47-53. DOI: 10.1111/j.1540-8167.2009.01563.x. |
| [54] |
FRONTERA A, HADJIS A, CALORE F, et al. Simultaneous endo-epicardial-high density mapping of ventricular tachycardia with the use of multi-electrode mapping catheters[J]. Journal of Interventional Cardiac Electrophysiology: an International Journal of Arrhythmias and Pacing, 2020, 58: 365-367. DOI: 10.1007/s10840-020-00762-6. |
| [55] |
TUNG R, RAIMAN M, LIAO H, et al. Simultaneous Endocardial and Epicardial Delineation of 3D Reentrant Ventricular Tachycardia[J]. Journal of the American College of Cardiology, 2020, 75: 884-897. DOI: 10.1016/j.jacc.2019.12.044. |
| [56] |
ABDELWAHAB A, STEVENSON W, THOMPSON K, et al. Intramural Ventricular Recording and Pacing in Patients With Refractory Ventricular Tachycardia: Initial Findings and Feasibility With a Retractable Needle Catheter[J]. Circulation. Arrhythmia and Electrophysiology, 2015, 8: 1181-1188. DOI: 10.1161/CIRCEP.115.002940. |
| [57] |
DELLA BELLA P, BRUGADA J, ZEPPENFELD K, et al. Epicardial ablation for ventricular tachycardia: a European multicenter study[J]. Circulation. Arrhythmia and Electrophysiology, 2011, 4: 653-659. DOI: 10.1161/CIRCEP.111.962217. |
| [58] |
MATHEW S, FINK T, FEICKERT S, et al. Complications and mortality after catheter ablation of ventricular arrhythmias: risk in VT ablation (RIVA) score[J]. Clinical Research in Cardiology: Official Journal of the German Cardiac Society, 2022, 111: 530-540. DOI: 10.1007/s00392-021-01902-2. |
| [59] |
CERANTOLA M, SANTANGELI P. Epicardial access facilitated by carbon dioxide insufflation via intentional coronary vein exit: step-by-step description of the technique and review of the literature[J]. Journal of Interventional Cardiac Electrophysiology: an International Journal of Arrhythmias and Pacing, 2023, 66: 109-116. DOI: 10.1007/s10840-022-01338-2. |
| [60] |
ROMERO JE, DIAZ JC, ZEI PC, et al. Sustained Apnea for Epicardial Access With Right Ventriculography: The SAFER Epicardial Approach[J]. JACC. Clinical Electrophysiology, 2023, 9: 1487-1499. DOI: 10.1016/j.jacep.2023.05.016. |
| [61] |
LESHEM E, ZILBERMAN I, BARKAGAN M, et al. Temperature-Controlled Radiofrequency Ablation Using Irrigated Catheters: Maximizing Ventricular Lesion Dimensions While Reducing Steam-Pop Formation[J]. JACC. Clinical Electrophysiology, 2020, 6: 83-93. DOI: 10.1016/j.jacep.2019.08.015. |
| [62] |
FUTYMA P, SULTAN A, ZARĘBSKI Ł, et al. Bipolar radiofrequency ablation of refractory ventricular arrhythmias: results from a multicentre network[J]. Europace: European Pacing, Arrhythmias, and Cardiac Electrophysiology: Journal of the Working Groups on Cardiac Pacing, Arrhythmias, and Cardiac Cellular Electrophysiology of the European Society of Cardiology, 2024, 26: euae248. DOI: 10.1093/europace/euae248. |
| [63] |
MENKOVIC I, BUTZKE DA MOTTA H, CERANTOLA M, et al. Endoepicardial transmural lesion formation utilizing multipolar radiofrequency ablation[J]. Heart Rhythm, 2026, 23: 1114-1119. DOI: 10.1016/j.hrthm.2025.05.020. |
| [64] |
BRUGADA P, DE SWART H, SMEETS JL, et al. Transcoronary chemical ablation of ventricular tachycardia[J]. Circulation, 1989, 79: 475-482. DOI: 10.1161/01.cir.79.3.475. |
| [65] |
TOKUDA M, SOBIESZCZYK P, EISENHAUER AC, et al. Transcoronary ethanol ablation for recurrent ventricular tachycardia after failed catheter ablation: an update[J]. Circulation. Arrhythmia and Electrophysiology, 2011, 4: 889-896. DOI: 10.1161/CIRCEP.111.966283. |
| [66] |
NGUYEN DT, GERSTENFELD EP, TZOU WS, et al. Radiofrequency Ablation Using an Open Irrigated Electrode Cooled With Half-Normal Saline[J]. JACC. Clinical Electrophysiology, 2017, 3: 1103-1110. DOI: 10.1016/j.jacep.2017.03.006. |
| [67] |
VERMA A, ESSEBAG V, NEUZIL P, et al. Cryocure-VT: the safety and effectiveness of ultra-low-temperature cryoablation of monomorphic ventricular tachycardia in patients with ischaemic and non-ischaemic cardiomyopathies[J]. Europace: European Pacing, Arrhythmias, and Cardiac Electrophysiology: Journal of the Working Groups on Cardiac Pacing, Arrhythmias, and Cardiac Cellular Electrophysiology of the European Society of Cardiology, 2024, 26: euae076. DOI: 10.1093/europace/euae076. |
| [68] |
CUCULICH PS, SCHILL MR, KASHANI R, et al. Noninvasive Cardiac Radiation for Ablation of Ventricular Tachycardia[J]. The New England Journal of Medicine, 2017, 377: 2325-2336. DOI: 10.1056/NEJMoa1613773. |
| [69] |
SACHER F, SARKOZY A, PÜRERFELLNER H, et al. Safety and efficacy of a lattice-tip catheter for ventricular arrhythmia ablation: the AFFERA Ventricular Arrhythmia Ablation Registry (AVAAR)[J]. Europace: European Pacing, Arrhythmias, and Cardiac Electrophysiology: Journal of the Working Groups on Cardiac Pacing, Arrhythmias, and Cardiac Cellular Electrophysiology of the European Society of Cardiology, 2025, 27: euaf139. DOI: 10.1093/europace/euaf139. |
| [70] |
DASA O, YOUNIS A, HIGUCHI K, et al. Early U.S. Experience With Catheter Ablation of Ventricular Arrhythmias With a Dual-Energy Lattice-Tip Catheter: Insights From the CLEAR-VT Registry[J]. JACC. Clinical Electrophysiology, 2026. DOI: 10.1016/j.jacep.2026.03.002. |
/
| 〈 |
|
〉 |