Skirted Prosthetic Valves Are Associated With Increased Risk of Subclinical Leaflet Thrombosis Following Transcatheter Aortic Valve Replacement: A Multicenter Study
Yifan Yang , Qiang Li , Jing Yao , Yunfeng Yan , Moyang Wang , Xinmin Liu , Fei Yuan , Zhengming Jiang , Taiyang Luo , Qian Zhang , Yongjian Wu , Guangyuan Song
Reviews in Cardiovascular Medicine ›› 2026, Vol. 27 ›› Issue (9) : 49694
Subclinical leaflet thrombosis (SLT) is associated with an increased risk of thromboembolic events, valve dysfunction, and mortality in patients undergoing transcatheter aortic valve replacement (TAVR). However, data on the incidence and risk factors for SLT in patients undergoing TAVR using self-expanding valves (SEVs) remain limited.
This study included patients who underwent TAVR using SEVs and received a postoperative four-dimensional computed tomography scan within six months at Beijing Anzhen Hospital and Fuwai Hospital. SLT was defined as the presence of hypo-attenuated leaflet thickening (HALT) with or without reduced leaflet motion (RLM), and characterized by increased leaflet thickness affecting one or more leaflets. Univariate and multivariable logistic regression analyses were conducted to explore the relationship between variables and the occurrence of SLT.
A total of 311 patients (mean age 72.02 ± 8.23 years, 52.4% males) were included in the analysis. HALT was detected in 91 patients (29.3%), while RLM was observed in 45 patients (14.5%). Most HALT (81.3%) and RLM (73.3%) cases were classified as grades 1–2. Multivariable logistic regression analysis revealed that using skirted prosthetic valves was significantly associated with SLT (adjusted odds ratio: 2.999; 95% confidence interval: 1.250–7.397; p = 0.015).
Over one-quarter of patients undergoing TAVR using SEVs developed SLT within six months. The use of skirted prosthetic valves was independently associated with SLT.
subclinical leaflet thrombosis / hypo-attenuated leaflet thickening / transcatheter aortic valve replacement / self-expanding valves
| [1] |
PRAZ F, BORGER MA, LANZ J, et al. 2025 ESC/EACTS Guidelines for the management of valvular heart disease[J]. European Heart Journal, 2025, 46: 4635-4736. DOI: 10.1093/eurheartj/ehaf194. |
| [2] |
BLANKE P, LEIPSIC JA, POPMA JJ, et al. Bioprosthetic Aortic Valve Leaflet Thickening in the Evolut Low Risk Sub-Study[J]. Journal of the American College of Cardiology, 2020, 75: 2430-2442. DOI: 10.1016/j.jacc.2020.03.022. |
| [3] |
OTSUKA Y, ISHII M, TABATA N, et al. Subclinical leaflet thrombus in patients with severe aortic stenosis and atrial fibrillation -ENRICH-AF TAVI study[J]. Scientific Reports, 2024, 14: 14902. DOI: 10.1038/s41598-024-65600-5. |
| [4] |
FUKUI M, BAPAT VN, GARCIA S, et al. Deformation of Transcatheter Aortic Valve Prostheses: Implications for Hypoattenuating Leaflet Thickening and Clinical Outcomes[J]. Circulation, 2022, 146: 480-493. DOI: 10.1161/CIRCULATIONAHA.121.058339. |
| [5] |
RASHID HN, GOOLEY RP, NERLEKAR N, et al. Bioprosthetic aortic valve leaflet thrombosis detected by multidetector computed tomography is associated with adverse cerebrovascular events: a meta-analysis of observational studies[J]. EuroIntervention, 2018, 13: e1748-e1755. DOI: 10.4244/EIJ-D-17-01062. |
| [6] |
GARCIA S, FUKUI M, DWORAK MW, et al. Clinical Impact of Hypoattenuating Leaflet Thickening After Transcatheter Aortic Valve Replacement[J]. Circulation. Cardiovascular Interventions, 2022, 15: e011480. DOI: 10.1161/CIRCINTERVENTIONS.121.011480. |
| [7] |
CHITTURI KR, ALADIN AI, BRAUN R, et al. Bioprosthetic Aortic Valve Thrombosis: Definitions, Clinical Impact, and Management: A State-of-the-Art Review[J]. Circulation. Cardiovascular Interventions, 2024, 17: e014143. DOI: 10.1161/CIRCINTERVENTIONS.123.014143. |
| [8] |
KOO HJ, KANG J, KANG DY, et al. Native Sinus Hemodynamics and Thrombosis in Transcatheter Heart Valve: Effect of Implant Depth and Coronary Flow[J]. Journal of the American Heart Association, 2024, 13: e037105. DOI: 10.1161/JAHA.124.037105. |
| [9] |
MIDHA PA, RAGHAV V, CONDADO JF, et al. Valve Type, Size, and Deployment Location Affect Hemodynamics in an In Vitro Valve-in-Valve Model[J]. JACC. Cardiovascular Interventions, 2016, 9: 1618-1628. DOI: 10.1016/j.jcin.2016.05.030. |
| [10] |
QIU D, AZADANI AN. On the Three-dimensionality of Flow in the Neo-sinus and its Implications for Subclinical Leaflet Thrombosis[J]. Interactive Cardiovascular and Thoracic Surgery, 2022, 36: ivac263. DOI: 10.1093/icvts/ivac263. |
| [11] |
NG ACT, HOLMES DR, MACK MJ, et al. Leaflet immobility and thrombosis in transcatheter aortic valve replacement[J]. European Heart Journal, 2020, 41: 3184-3197. DOI: 10.1093/eurheartj/ehaa542. |
| [12] |
MARCHANDOT B, TRIMAILLE A, KIKUCHI S, et al. Subclinical Leaflet Thrombosis and Subclinical Aortic Valve Complex Thrombosis in TAVR[J]. JACC. Advances, 2025, 4: 102085. DOI: 10.1016/j.jacadv.2025.102085. |
| [13] |
PIBAROT P, HERRMANN HC, WU C, et al. Standardized Definitions for Bioprosthetic Valve Dysfunction Following Aortic or Mitral Valve Replacement: JACC State-of-the-Art Review[J]. Journal of the American College of Cardiology, 2022, 80: 545-561. DOI: 10.1016/j.jacc.2022.06.002. |
| [14] |
BLANKE P, WEIR-MCCALL JR, ACHENBACH S, et al. Computed Tomography Imaging in the Context of Transcatheter Aortic Valve Implantation (TAVI)/Transcatheter Aortic Valve Replacement (TAVR): An Expert Consensus Document of the Society of Cardiovascular Computed Tomography[J]. JACC. Cardiovascular Imaging, 2019, 12: 1-24. DOI: 10.1016/j.jcmg.2018.12.003. |
| [15] |
RASHID HN, MICHAIL M, IHDAYHID AR, et al. Prosthesis Geometrical Predictors of Leaflet Thrombosis Following Transcatheter Aortic Valve Replacement With Intra-Annular Prostheses[J]. Heart, Lung & Circulation, 2022, 31: 678-684. DOI: 10.1016/j.hlc.2021.11.013. |
| [16] |
BREITBART P, PACHE G, MINNERS J, et al. Influence of prosthesis-related factors on the occurrence of early leaflet thrombosis after transcatheter aortic valve implantation[J]. European Heart Journal. Cardiovascular Imaging, 2020, 21: 1082-1089. DOI: 10.1093/ehjci/jeaa139. |
| [17] |
VARC-3 WRITING COMMITTEE, GÉNÉREUX P, PIAZZA N, et al. Valve Academic Research Consortium 3: updated endpoint definitions for aortic valve clinical research[J]. European Heart Journal, 2021, 42: 1825-1857. DOI: 10.1093/eurheartj/ehaa799. |
| [18] |
ZOGHBI WA, ASCH FM, BRUCE C, et al. Guidelines for the Evaluation of Valvular Regurgitation After Percutaneous Valve Repair or Replacement: A Report from the American Society of Echocardiography Developed in Collaboration with the Society for Cardiovascular Angiography and Interventions, Japanese Society of Echocardiography, and Society for Cardiovascular Magnetic Resonance[J]. Journal of the American Society of Echocardiography, 2019, 32: 431-475. DOI: 10.1016/j.echo.2019.01.003. |
| [19] |
JUNG S, AMMON F, SMOLKA S, et al. Commissural misalignment independently predicts leaflet thrombosis after transcatheter aortic valve implantation[J]. Clinical Research in Cardiology, 2024, 113: 29-37. DOI: 10.1007/s00392-023-02192-6. |
| [20] |
SIMPSON TF, TUOHY CV, RAJOTTE K, et al. Bioprosthetic valve oversizing is associated with increased risk of valve thrombosis following TAVR[J]. Catheterization and Cardiovascular Interventions, 2021, 97: E411-E417. DOI: 10.1002/ccd.29104. |
| [21] |
SOLOMONICA A, CHOUDHURY T, BAGUR R. Newer-generation of Edwards transcatheter aortic valve systems: SAPIEN 3, Centera, and SAPIEN 3 Ultra[J]. Expert Review of Medical Devices, 2019, 16: 81-87. DOI: 10.1080/17434440.2019.1555465. |
Beijing Hospitals Authority’s Ascent Plan(DFL20240604)
/
| 〈 |
|
〉 |