The article is dedicated to computer-assisted external fixation devices, so-called hexapods. The main advantage of these frames is capability to make mathematically precise correction of bone fragments in three planes and six degrees of freedom on the base of calculations made in special software application. Recently these devices are mostly applied in long bone deformity correction but the sphere of its effective useis not limited by only this direction. The article presents the history of investigation of these devices, their development, implemented comparative analysis of the basic hexapods: TSF (Taylor Spatial Frame), IHA (Ilizarov Hexapod Apparatus) and Ortho-SUV Frame.

Keywords

external fixation / hexapods / computer navigation / deformity correction

Cite this article

Download citation ▾
Viktor Aleksandrovich Vilensky, Aleksander Pavlovich Pozdeev, Edgar Valentinovich Bukharev, Andrey Aleksandrovich Pozdeev, Timur Faizovich Zubairov, Leonid Nikolaevich Solomin. Orthopedic hexapods: history, present and prospects. Pediatric Traumatology, Orthopaedics and Reconstructive Surgery, 2015, 3(1): 61-69 DOI:10.17816/PTORS3161-69

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Виленский В.А. Разработка основ новой технологии лечения пациентов с диафизарными повреждениями длинных костей на базе чрескостного аппарата со свойствами пассивной компьютерной навигации: дис. … канд. мед. наук. СПб., 2009;284.

[2]

Кун С., Госселин К. Структурный синтез параллельных механизмов: пер. с англ. М.: Физматлит, 2012;276.

[3]

Скоморошко П.В. Оптимизация лечения больных с диафизарными деформациями бедренной кости на основе использования чрескостного аппарата со свойствами пассивной компьютерной навигации (экспериментально-клиническое исследование): дисс. … канд. мед. наук. СПб., 2014;224.

[4]

Соломин Л.Н., Виленский В.А., Утехин А.И., Террел В.Сравнительный анализ репозиционных возмож-ностей чрескостных аппаратов, работающих на основе компьютерной навигации и аппрата Илизарова //Гений ортопедии. Курган, 2009;(1):5-10.

[5]

Соломин Л.Н., Виленский В.А., Утехин А.И. Орто-СУВ-аппарат: чрескостный аппарат, работа которого основана на компьютерной навигациию // Гений ортопедии. 2011;(2):161-169.

[6]

Bonev I. The True Origins of Parallel Robots: http://www. parallemic.org/Reviews/Review007p.html, Jan; 24, 2003.

[7]

Eidelman M., Chezar A. Principles of deformity correction using the Taylor Spatial Frame. // Harefuah. 2005;144(2):152-158.

[8]

Feldman D.S., Shin S.S., Madan S.S., Koval K.J. Correction of tibial malunion and non-union with sixaxis analysis deformity correction using the Taylor Spatial Frame. // J. Orthop. Trauma. 2003;17:549-554.

[9]

Odesski J. Our experience of application the Ilizarov Hexapod Apparatus. 5th Meeting of the A.S.A.M.I. International: program and abstract book. St. Petersburg, 2008;60.

[10]

Paley D. History and science behind the six-axis correction external fixation devices in orthopaedic surgery. // Oper Tech Orthop. 2011;21:125-128.

[11]

Paley D. Principles of deformity correction. New York: Springer-Verlag, 2005;806.

[12]

Samchukov M., Cherkashin A., Ross D. Hexapod external fixation: Advantages and clinical applications. J.O.R.I.M ( Japanes Association of Orthopedic Reconstruction and Ilizarov Method): program and abstract book. Tokio, 2014; 23.

[13]

Segev E., Hemo Y., Wientroub S. Intra- and interobserver reliability analysis of digital radiographic measurements for pediatric orthopedic parameters using a novel PACS integrated computer software program. // Journal of Children’s Orthopaedics 2010;4(4):331-341. doi:10.1007/ s11832-010-0259-5.

[14]

Seide K., Wolter D., Kortmann H.R. Fracture reduction and deformity correction with the hexapod Ilizarov fixator. // Clin Orthop. 1999;6:186-195.

[15]

Shevtsov V.I., Mishina N.I. The Ilizarov method as fundamental and motive force of international ASAMI.5th Meeting of the A.S.A.M.I. International: program and abstract book. St. Petersburg, 2008;46.

[16]

Solomin L.N., Paley D., Shchepkina E.A., Vilensky V.A., Skomoroshko P.V. A comparative study of the correction of femoral deformity between the Ilizarov apparatus and Ortho-SUV Frame. // Int Orthop. 2014 Apr; 38(4):865-72.

[17]

Solomin L.N. The basic principles of external skeletal fixation using the Ilizarov and other devices. 2nd Edition. Springer-Verlag, Milan Heidelberg, New-York, 2012;1593.

[18]

Stewart D. A platform with six degrees of freedom.Proceedings of the Institute of Mechanical Engineers.1965;180(1):371-386.

[19]

Takata M., Vilensky V.A., Tsuchiya H., Solomin L.N. Foot deformity correction with hexapod external fixator, the Ortho-SUV Frame™. // J Foot Ankle Surg. 2013 May- Jun;52(3):324-30.

[20]

Taylor J.C. A new look at deformity correction. Distraction. // The Newsletter of ASAMI-North America. 1997;5(1).

[21]

Taylor Spatial Frame (TSF) - Motorised Ilizarov alternative, Hexapod - Orthopaedic ring fixator. 2009. http://www.youtube.com/watch?v=VfZhVRDAKVA (дата обращения: 11.02.2015)

RIGHTS & PERMISSIONS

Vilensky V.A., Pozdeev A.P., Bukharev E.V., Pozdeev A.A., Zubairov T.F., Solomin L.N.

AI Summary AI Mindmap
PDF

139

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/