Reimplantation of a drainage valve device in refractory glaucoma. A clinical case

Anna V. Starostina , Margarita R. Khabazova , Konstantin S. Burlakov , Alexey A. Arisov

Journal of Clinical Practice ›› 2022, Vol. 13 ›› Issue (2) : 114 -120.

PDF
Journal of Clinical Practice ›› 2022, Vol. 13 ›› Issue (2) : 114 -120. DOI: 10.17816/clinpract107179
Case reports
research-article

Reimplantation of a drainage valve device in refractory glaucoma. A clinical case

Author information +
History +
PDF

Abstract

Background: Implantation of various drainage devices is one of the treatments for refractory glaucoma, resistant to traditional surgical methods. The most commonly used glaucoma drainage device for refractory glaucoma is the Ahmed glaucoma valve. However, the long-term success rate of the surgery may be limited because of the development of complications during the late postoperative period. The complications do not allow the control of the achieved intraocular pressure (IOP) level. In such cases, a repeated implantation of the Ahmed valve may be one of the options for the surgical treatment. Clinical case description: Second Ahmed valves were implanted to two patients with refractory repeatedly operated glaucoma at the Department of surgical glaucoma treatment of the S. Fyodorov Eye Microsurgery Federal State Institution in Moscow. Previously, both patients had the Ahmed valves installed at their places of residence. During the postoperative period, one patient was found to have an encapsulated cyst around the drainage body, and later the revision of the operation area was performed. As a result of the repeated Ahmed valve implantation, the IOP compensation was achieved 9 months after the surgery. Conclusion: A repeated implantation of the Ahmed valve may be an option for the surgical treatment, if the first implant failed to control the IOP, in order to compensate the IOP and preserve the visual functions in patients with refractory repeatedly operated glaucoma.

Keywords

refractory glaucoma / valve drainage / Ahmed valve / intraocular pressure

Cite this article

Download citation ▾
Anna V. Starostina, Margarita R. Khabazova, Konstantin S. Burlakov, Alexey A. Arisov. Reimplantation of a drainage valve device in refractory glaucoma. A clinical case. Journal of Clinical Practice, 2022, 13(2): 114-120 DOI:10.17816/clinpract107179

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Luzu J, Baudouin C, Hamard P. The role of Ahmed glaucoma valve in the management of refractory glaucoma: long-term outcomes and complications. Eur J Ophthalmol. 2021;31(5): 2383–2389. doi: 10.1177/1120672120968733

[2]

Budenz DL, Barton K, Feuer WJ, et al. Treatment outcomes in the Ahmed Baerveldt Comparison Study after 1 year of follow-up. Ophthalmology. 2011;118(3):443–452. doi: 10.1016/j.ophtha.2010.07.016

[3]

Papadaki TG, Zacharopoulos IP, Pasquale LR, et al. Long-term results of Ahmed glaucoma valve implantation for uveitic glaucoma. Am J Ophthalmol. 2007;144(1):62–69. doi: 10.1016/j.ajo.2007.03.013

[4]

Christakis PG, Kalenak JW, Zurakowski D, et al. The Ahmed Versus Baerveldt study: one-year treatment outcomes. Ophthalmology. 2011;118(11):2180–2189. doi: 10.1016/j.ophtha.2011.05.004

[5]

Ong SC, Aquino MC, Chew P, Koh V. Surgical outcomes of a second Ahmed glaucoma valve implantation in Asian eyes with refractory glaucoma. J Ophthalmol. 2020;2020:8741301. doi: 10.1155/2020/8741301

[6]

Coleman AL, Hill R, Wilson MR, et al. Initial clinical experience with the Ahmed glaucoma valve implant. Am J Ophthalmol. 1995;120(1):23–31. doi: 10.1016/s0002-9394(14)73755-9

[7]

Kirmaci Kabakci A, Solmaz B, Basarir B, et al. Non-intraocular pressure-related revision surgeries after Ahmed glaucoma valve (AGV) implantation in refractory glaucoma. Int Ophthalmol. 2021;41(10):3533–3538. doi: 10.1007/s10792-021-01920-z

[8]

Расческов А.Ю. Разработка хирургической технологии имплантации клапанной дренажной системы в лечении рефрактерной глаукомы: Дис. … канд. мед. наук. Москва, 2012. 120 с. [Rascheskov AY. Development of surgical technology of implantation of the valve drainage system in the treatment of refractory glaucoma [dissertation]. Moscow; 2012. 120 р. (In Russ).]

[9]

Shah AA, Wu Dunn D, Cantor LB. Shunt revision versus additional tube shunt implantation after failed tube shunt surgery in refractory glaucoma. Am J Ophthalmol. 2000;129(4):455–460. doi: 10.1016/s0002-9394(99)00410-9

[10]

Fatehi N, Morales E, Parivisutt N, et al. Long-term outcome of second ahmed valves in adult glaucoma. Am J Ophthalmol. 2018;186:96–103. doi: 10.1016/j.ajo.2017.11.018

[11]

Патент РФ № 2768189 от 26.07.2021. Старостина А.В., Сидорова А.В., Халецкая А.А., и др. Способ хирургического лечения рубцевания теноновой капсулы вокруг антиглаукомного клапана Ahmed. [RF Patent No. 2768189 dated 26.07.2021. Starostina AV, Sidorova AV, Khaletskaya AA, et al. Method of surgical treatment of scarring of the tenon capsule around the Ahmed antiglaucoma valve. (In Russ).] Режим доступа: https://patents.google.com/patent/RU2768189C1/ru. Дата обращения: 12.04.2022.

[12]

Posarelli C, Toro MD, Rejdak R, et al. Safety and efficacy of second ahmed valve implant in refractory glaucoma. J Clin Med. 2020;9(7):2039. doi: 10.3390/jcm9072039

[13]

Smith M, Buys YM, Trope GE. Second Ahmed valve insertion in the same eye. J Glaucoma. 2009;18(4):336–340. doi: 10.1097/IJG.0b013e318182edfb

[14]

Nilforushan N, Yadgari M, Jazayeri AA, Karimi N. Evaluation of success after second Ahmed glaucoma valve implantation. Indian J Ophthalmol. 2016;64(3):206–210. doi: 10.4103/0301-4738.181740

[15]

Becerril-Cazadero R, Seibold LK, Turati-Acosta M, et al. Surgical outcomes of a second Ahmed glaucoma valve implant for the treatment of refractory glaucoma. J Glaucoma. 2020;29(10):948–951. doi: 10.1097/ijg.0000000000001585

Funding

ФГАУ «МНТК «Микрохирургия глаза» имени академика С.Н. Федорова» Минздрава РоссииS.N. Fedorov National Medical Research Center “MNTK “Eye Microsurgery”

RIGHTS & PERMISSIONS

Starostina A.V., Khabazova M.R., Burlakov K.S., Arisov A.A.

AI Summary AI Mindmap
PDF

113

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/