Influence of the cross-sectional shape and length of the compressible sections on the characteristics of a linear peristaltic pump

A. I Grishin

Izvestiya MGTU MAMI ›› 2021, Vol. 15 ›› Issue (2) : 9 -17.

PDF
Izvestiya MGTU MAMI ›› 2021, Vol. 15 ›› Issue (2) : 9 -17. DOI: 10.31992/2074-0530-2021-48-2-9-17
Articles
research-article

Influence of the cross-sectional shape and length of the compressible sections on the characteristics of a linear peristaltic pump

Author information +
History +
PDF

Abstract

In the overview part of the work, the most common existing designs of pumps of the peristaltic principle of operation, as well as the main areas of their application, are briefly presented. The main part of the work is devoted to the study of the influence on the operation of a peristaltic pump with a linearly arranged tube of the shape of the cross-section of the tube in the region of the compressible sections, as well as the ratio of the sizes of the release elements periodically compressing the pump tube in the transverse direction. The studies were carried out through numerical experiments in the STAR-CCM + program, which is based on the control volume method. As a result of the carried out calculations, it was found that the use of protrusions on the inner surface of the tube gives a positive effect if the protrusions have a special curvilinear shape with a smooth transition near the inner surface of the tube, and the increase in the generated pressure and feed is greater if the protrusions are present only in the compression region tube with the first squeeze element. In this case, the discharge angle of the pump characteristic changes so that a positive effect is not observed in the region of small values of the generated pressure. The study of the influence of different ratios of the lengths of the compressible sections of the tube on the flow and pressure created by the pump showed that for the incomplete compression of the pump tube investigated in the work, the use of squeeze elements of the same length is favorable. Both for a tube without protrusions and for a tube with protrusions, the use of a second squeeze element of greater or lesser length than the length of the remaining squeeze elements with the same total length of all three compressible sections leads to an increase in leakage when the tube is not fully compressed, and thus reduces the pump flow.

Keywords

peristaltic pump / fluid-solid interaction / computational fluid dynamics

Cite this article

Download citation ▾
A. I Grishin. Influence of the cross-sectional shape and length of the compressible sections on the characteristics of a linear peristaltic pump. Izvestiya MGTU MAMI, 2021, 15(2): 9-17 DOI:10.31992/2074-0530-2021-48-2-9-17

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Latham T. W. Fluid motion in a peristaltic pump. Massachusetts Institute of Technology, 1966. 74 p.

[2]

Михеев А.Ю. Исследование характеристики и повышение надежности насосов перистальтического принципа действия: дис. … канд. техн. наук. Уфа, 2004. 168 c.

[3]

Loudin T. The evolution of peristaltic pump // Pump engineer. Zutphen, Netherlands: KCI Publishing, September 2007. P. 44-47.

[4]

Левицкий А.А., Левицкая З.В., Ситников А.М. Компоненты микросистемной техники. Лабораторный практикум. Красноярск: СФУ, 2007. 85 с.

[5]

WG600F Intelligent Industrial Peristaltic Pump [Электронный ресурс]. Режим доступа: http://www.nanbei-china.com/product/laboratory/pump/type/2014/0108/717.html.

[6]

BT300L Intelligent flow peristaltic pump [Электронный ресурс]. Режим доступа: http://www.nanbei-china.com/product/laboratory/pump/flow/2014/0107/702.html.

[7]

Trenkle F., Haeberle S., Zengerle R. Normally-closed peristaltic micropump with re-usable actuator and disposable fluidic chip // Sensors and Actuators B: Chemical. 2010. No 154. P. 137-141.

[8]

Dreckmann T., Boeuf J., Ludwig I., Lümkemanna J., Huwylerc J. Low volume aseptic filling: Impact of pump systems on shear stress // European Journal of Pharmaceutics and Biopharmaceutics. Elsevier 2020. No 147. P. 10-18. DOI: 10.1016/j.ejpb.2019.12.006.

[9]

Порядков Л.Ф. Рабочая трубка для перистальтического насоса // Патент на изобретение № 309294, Российская Федерация. Опубликовано 27.10.2007. Бюл. № 30.

[10]

Тарасов Ю.Д. Перистальтический насос // Патент на изобретение № 2290536, Российская Федерация. Опубликовано 27.12.2006. Бюл. № 36.

[11]

Shkolnikov V., Ramunas J., Santiago J. A self-priming, roller-free, miniature, peristaltic pump operable with a single, reciprocating actuator // Sensors and Actuators A: Physical. Elsevier. 2010. P. 141-146 DOI:10.1016/j.sna.2010.04.018.

[12]

Гришин А.И. Повышение эффективности эксплуатации перистальтического насоса линейного типа // Известия МГТУ «МАМИ». 2020. № 4. С. 17-26.

RIGHTS & PERMISSIONS

Grishin A.I.

AI Summary AI Mindmap
PDF

61

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/