An effective method of surgical treatment of refractory glaucoma patients using Ex-PRESSTM filtering device

Sergey Yuryevich Astakhov , Ahmed Alievich Harsha

Ophthalmology Reports ›› 2013, Vol. 6 ›› Issue (1) : 3 -8.

PDF
Ophthalmology Reports ›› 2013, Vol. 6 ›› Issue (1) : 3 -8. DOI: 10.17816/OV201313-8
Articles
other

An effective method of surgical treatment of refractory glaucoma patients using Ex-PRESSTM filtering device

Author information +
History +
PDF

Abstract

Based on data obtained from examination and subsequent follow-up of 47 patients (50 eyes) with refractory glaucoma, an efficacy estimation of a new method of the Ex-PRESSTM filtering device implantation was performed. The data analysis showed that the proposed surgical procedure has a low level of intra- and post-operative complications, is characterized by technical ease, and provides a long term stabilization of the glaucomatous process. Therefore it is possible to draw a conclusion that the Ex-PRESSTM filtering device implantation is an effective method for the treatment of refractory glaucoma.

Keywords

refractory glaucoma / Ex-PRESSTM filtering device

Cite this article

Download citation ▾
Sergey Yuryevich Astakhov, Ahmed Alievich Harsha. An effective method of surgical treatment of refractory glaucoma patients using Ex-PRESSTM filtering device. Ophthalmology Reports, 2013, 6(1): 3-8 DOI:10.17816/OV201313-8

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Астахов С. Ю., Астахов Ю. С. Современные тенденции в хирургическом лечении глауком // Глаукома: проблемы и решения: Сб. статей Всерос. науч.-практ. конф. — М., 2004. — С. 256–262.

[2]

Бессмертный А. М., Еричев В. П. Алгоритм хирургического лечения рефрактерной глаукомы // Глаукома: проблемы и решения: Сб. статей Всерос. науч.-практ. конф. — М., 2004. — С. 271–272.

[3]

Еричев В. П. Хирургическое и ультразвуковое лечение основных форм рефрактерной глаукомы: Автореф. дис. … д-ра. мед. наук: 14.00.08. — М., 1998. — 52 с.

[4]

Касимов Э. М., Керимов К. Т. Профилактика избыточного рубцевания склеры у пациентов с открытоугольной глаукомой // Современные аспекты диагностики и лечения заболеваний органа зрения. — Баку, 2001. — С. 115–122.

[5]

Корчуганова Е. А. Лимбосклерэктомия с клапанным дренированием супрацилиарного пространства — новая операция в лечении рефрактерных глауком: Автореф. дис. … канд. мед. наук: 14.00.08. — М., 2001. — 27 с.

[6]

Нестеров А. П. Глаукома. — М.: Медицина, 1995. — 255 с.

[7]

Черных Е. Н., Захарова И. А. Оценка отдаленных результатов антиглаукоматозных операций у больных с рефрактерными видами глаукомы // Глаукома: теории, тенденции, технологии. HRT Клуб Россия. — М., 2009. — С. 561–571.

[8]

Ahmed I. K. Ex-PRESS mini glaucoma shunt: techniques and pearls // Clin. & Surgical Ophthalmol. — Ahmed 2008. — Vol. 26, N 9. — P 306–310.

[9]

Beiran I., Rootman D. S., Trope G. E., Buys Y. M. Long-term results of transscleral Nd: YAG cyclophotocoagulation for refractory glaucoma postpenetrating keratoplasty // J. Glaucoma. — 2000. — Vol. 9, N 3. — P. 268–272.

[10]

Budenz D. L., Scott I. U., Nguyen Q. H. et al. Combined Baerveldt glaucoma drainage implant and trabeculectomy with mitomycin C for refractory glaucoma // J. Glaucoma. — 2002. — Vol. 11, N 5. — P. 439–445.

[11]

Chen C. W., Huang H. T., Bair J., Lee C. Trabeculectomy with simultaneous topical application of mitomycin-C in refractory glaucoma // J. Ocul. Pharmacol. — 1990. — Vol. 6, N 3. — P. 175–182.

[12]

Dahan E., Mermoud A. The Ex-PRESS™ miniature glaucoma implant. — Glaucoma. Surgical Management, Vol. 2. — Saunders Elsevier. — 2010. — P. 157–164.

[13]

Francis B. A., Kudlev Singh, Lin Sh. C. et al. Novel glaucoma procedures. A report by the American Academy of Ophthalmology // Ophthalmol. — 2011. — Vol. 118, N 7. — P. 1446–1480.

[14]

Good T. J., Kahook M. Y. Assessment of bleb morphologic features and postoperative outcomes after Ex-PRESS drainage device implantation versus trabeculectomy // Am. J. Ophthalmol. — 2011. — Vol. 151, N 3. — P. 507–513.

[15]

Katz L. J. Tube shunts for refractory glaucomas // Duane’s Clinical Ophthalmology. — Philadelphia, 2003. — Chap. 17.

[16]

Kook M. S., Yoon J., Kim J., Lee M. S. Clinical results of Ahmed glaucoma valve implantation in refractory glaucoma with adjunctive mitomycin C // Ophthalmic Surg. Lasers. — 2000. — Vol. 31, N 2. — P. 100–106.

[17]

Maris P. J. G., Ishida K., Netland P. A. Comparison of trabeculectomy with Ex-PRESS miniature glaucoma device implanted under sclera flap // J. Glaucoma. — 2007. — Vol. 16 N 1. — P. 14–19.

[18]

Nyska A., Glovinsky Y., Belkin M. et al. Biocompatibility of the Ex-PRESS miniature glaucoma drainage implant // J. Glaucoma. — 2003. — Vol. 12, N 3. — P. 275–280.

[19]

Roy S., Ravinet E., Mermoud A. Baerveldt implant in refractory glaucoma: long-term results and factors influencing outcome // Int. Ophthalmol. — 2001. — Vol. 24, N 2. — P. 93–100.

[20]

Shah A. A., WuDunn D., Cantor L. B. Shunt revision versus additional tube shunt implantation after failed tube shunt surgery in refractory glaucoma // Am. J. Ophthalmol. — 2000. — Vol. 129, N 4. — P. 455–460.

[21]

Stewart W. C., Brindley G. O., Shields M. B. Cyclodestructive procedures // The glaucomas / Ed. by R. Ritch et al. — 2nd ed. — St. Louis, 1996. — Vol. 3. — Chap. 79.

[22]

Verbraak F. D., De Bruin D. M., Sulak M. L. et al. Optical coherence tomography of the Ex-PRESS™ miniature glaucoma implant // Lasers Med. Sci. — 2005. — Vol. 20. — P. 41–44.

[23]

Wamsley S., Moster M. R., Rai. S. et al. Results of the use of the Ex-PRESS miniature glaucoma implant in technically challenging, advanced glaucoma cases: a clinical pilot study // Am. J. Ophthalmol. — 2004. — Vol. 138. — P. 1049–1051.

RIGHTS & PERMISSIONS

Astakhov S.Y., Harsha A.A.

AI Summary AI Mindmap
PDF

135

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/