Antenatal cardiotocography: problems and facilitiies
Nataliya Grigor’yevna Pavlova
Journal of obstetrics and women's diseases ›› 2015, Vol. 64 ›› Issue (2) : 64 -68.
Antenatal cardiotocography: problems and facilitiies
The role of antenatal cardiotocography (CTG) in algorithm of fetal functional conditions disorders diagnosis is discussed in this article. Furthermore, visual and computer analysis of antenatal monitoring results have been compared. There were discussed Dawes-Redman criteria and based on them CTG systems of computer numeral analysis (Sonicaid System 8000, Sonicaid System 8002, Sonicaid FetalCare). There were shown that based principles of antenatal CTG registrations should be kept in any case, its analysis is possible only in time of active phase of the fetus rest-activity cycle. Any kind of questionable tracing should be analyzed by medical expert in special centers with appropriate experience.
fetal / antenatal cardiotocography / criteria Daws-Redman / visual and computer analysis kardiotokogramm
| [1] |
Гармашева Н. Л., ред. Патофизиология внутриутробного развития. Л.: Медгиз; 1959. |
| [2] |
Павлова Н. Г., Аржанова О. Н., Зайнулина М. С., Колобов А. В., Айламазян Э. К., ред. Плацентарная недостаточность: учебно-методическое пособие. СПб.: Изд-во Н-Л; 2007. |
| [3] |
Павлова Н. Г., Коган И. Ю., Константинова Н. Н., Айламазян Э. К., ред. Кардиотокография: учебно-методическое пособие. СПб.: Изд-во Н-Л; 2009. |
| [4] |
Chauhan S. P., Klauser C. K., Woodring T. C. et al. Intrapartum nonreassuring fetal heart rate tracing and prediction of adverse outcomes: interobserver variability. Amer. J. Obstet Gynecol. 2008; 199 (6): 623.e1-5. |
| [5] |
Dawes G. S., Moulden M., Redman C. W. G. Short-term fetal heart rate variation, decelerations and umbilical flow velocity waveforms before labour. Obstet. Gynecol. 1992; 80: 673-8. |
| [6] |
Dawes G. S., Moulden M., Redman C. W. G. The advantages of computerized fetal heart rate analysis. J. Perinat. Med. 1991; 19: 39-45. |
| [7] |
Devoe L., Golde S, Kilman Y. et al. A comparison of visual analyses of intrapartum fetal heart rate tracings according to the new national institute of child health and human development guidelines with computer analyses by an automated fetal heart rate monitoring system. Amer. J. Obstet Gynecol. 2000; 183 (2): 361-6. |
| [8] |
Guzman E. R., Vintzileos A. M., Martins et al. The efficacy of individual computer heart rate indices in detecting acidemia at birth in growth-restricted fetuses. Obstet.Gynecol. 1996; 87: 969-4. |
| [9] |
Hensen G. L., Dawes G. S., Redman C. W. G. Antenatal fetal heart-rate variability in relation to fetal acid-base status at caesarean section. Br. J. Obstet. Gynaecol. 1983; 88: 792-802. |
| [10] |
Mantel R., van Geijn H. P., Ververs I. A.P., Copray F. J. A. Automated analysis of near-term antepartum fetal heart rate in relation to fetal behavioural states - the Sonicaid system 8000. Amer. J. Obstet Gynecol. 1991; 165: 57-65. |
| [11] |
Pardey J., Moulden M., Redman C. W. A computer system for the numerical analysis of nonstress tests. Amer. J. Obstet.Gynec. 2002; 186: 1095-1103. |
| [12] |
Pavlova N. G., Konstantinova N. N., Arutjunyan A. V. Functional and Biochemical Criteria for Investigation of Brain Development Disorders. Int. J. of Devl. Neuroscience. 1999; 17 (8): 839-48. |
| [13] |
Reddy A., Moulden M., Redman C. W. Antepartum high-frequency fetal heart rate sinusoidal rhythm: computerized detection and fetal anemia. Amer. J. Obstet.Gynec. 2009; 200 (4): 407. e1-6. |
Pavlova N.G.
/
| 〈 |
|
〉 |