Evaluation of the effectiveness of innovative methods of focused ultrasound and uterine artery embolization in the treatment of uterine fibroids

Lyudmila V. Kaushanskaya , Zareta M. Gatagazheva , Zukhra K. Uzdenova , Malika M. Gatagazheva , Khava A. Arsanukaeva , Nesredin A. Makhmudov , Darya P. Minigulova

Journal of obstetrics and women's diseases ›› 2024, Vol. 73 ›› Issue (3) : 61 -68.

PDF
Journal of obstetrics and women's diseases ›› 2024, Vol. 73 ›› Issue (3) : 61 -68. DOI: 10.17816/JOWD629136
Original study articles
research-article

Evaluation of the effectiveness of innovative methods of focused ultrasound and uterine artery embolization in the treatment of uterine fibroids

Author information +
History +
PDF

Abstract

BACKGROUND: Uterine fibroids are one of the most common gynecological diseases. The application of innovative techniques such as focused ultrasound ablation and uterine artery embolization has improved the quality of life of many patients. However, despite significant advances in innovative therapies, there is no certainty about the long-term efficacy of focused ultrasound ablation and uterine artery embolization.

AIM: The aim of this study was to compare the efficacy of focused ultrasound ablation and uterine artery embolization treatments of uterine fibroids.

MATERIALS AND METHODS: This study analyzed observations of 112 patients with uterine fibroids. Patients in the first group were treated with focused ultrasound ablation (n = 44). The second group of patients underwent uterine artery embolization (n = 68).

RESULTS: The study groups differed in the reduction of myomatous node sizes one, three, six and 12 months after surgery, depending on the chosen treatment method (p < 0.001). In the first group, fibroid volume decreased by 14% after a month and by 35% after 12 months. In the second group, it decreased by 20% after a month and by 54% after a year.

CONCLUSIONS: Treatment with the uterine artery embolization method reduced fibroid volume by 54%, which is 19% more effective than the focused ultrasound ablation method.

Keywords

uterine fibroids / focused ultrasound / uterine artery embolization

Cite this article

Download citation ▾
Lyudmila V. Kaushanskaya, Zareta M. Gatagazheva, Zukhra K. Uzdenova, Malika M. Gatagazheva, Khava A. Arsanukaeva, Nesredin A. Makhmudov, Darya P. Minigulova. Evaluation of the effectiveness of innovative methods of focused ultrasound and uterine artery embolization in the treatment of uterine fibroids. Journal of obstetrics and women's diseases, 2024, 73(3): 61-68 DOI:10.17816/JOWD629136

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Meriakri AV. Epidemiology and pathogenesis of myoma uteri. Siberian Medical Journal (Irkutsk).1998;13(2):8–13. EDN: RVPCZJ

[2]

Мериакри А.Д. Эпидемиология и патогенез миомы матки // Сибирский медицинский журнал. 1998. Т. 13, № 2. С. 8–13. EDN: RVPCZJ

[3]

Stewart EA, Gedroyc WM, Tempany CM, et al. Focused ultrasound treatment of uterine fibroid tumors: safety and feasibility of a noninvasive thermoablative technique. Am J Obstet Gynecol. 2003;189(1):48–54. doi: 10.1067/mob.2003.345

[4]

Stewart E.A., Gedroyc W.M., Tempany C.M., et al. Focused ultrasound treatment of uterine fibroid tumors: safety and feasibility of a noninvasive thermoablative technique // Am J Obstet Gynecol. 2003. Vol. 189, N. 1. P. 48–54. doi: 10.1067/mob.2003.345

[5]

Slabozhankina EA, Kitaev VM, Kira EF. The effectiveness of ultrasound hifu-ablation of uterine fibroids, depending on the type of MR fibroids. Bulletin of the National Medical and Surgical Center named after N.I.Pirogov. 2015;10(1):51–55. EDN: WMPBTP

[6]

Слабожанкина Е.А., Китаев В.М., Кира Е.Ф. Эффективность ультразвуковой HIFU-абляции миомы матки в зависимости от МР-типов миоматозных узлов // Вестник национального медико-хирургического центра им. Н.И. Пирогова. 2015. Т. 10, № 1. С. 51–55. EDN: WMPBTP

[7]

Sosnova EA, Malysheva YR. Methods of the treatment of uterine myoma: Literature review. V.F. Snegirev Archives of Obstetrics and Gynecology. 2017;4(1):20–28. EDN: XWKTQT doi: 10.18821/2313-8726-2017-4-1-20-28

[8]

Соснова Е.А., Малышева Я.Р. Методы лечения миомы матки: обзор литературы // Архив акушерства и гинекологии им. В.Ф. Снегирева. 2017. Т. 4, № 1. C. 20–28. EDN: XWKTQT doi: 10.18821/2313-8726-2017-4-1-20-28

[9]

Edwards RD, Moss JG, Lumsden MA, et al. Uterine-artery embolization versus surgery for symptomatic uterine fibroids. N Engl J Med. 2007;356(4):360–370. doi: 10.1056/NEJMoa062003

[10]

Edwards R.D., Moss J.G., Lumsden M.A., et al. Uterine-artery embolization versus surgery for symptomatic uterine fibroids // N Engl J Med. 2007. Vol. 356, N. 4. P. 360–370. doi: 10.1056/NEJMoa062003

[11]

Devyatova EA, Tsaturova KA, Esmurzieva ZI, et al. Uterine myoma. Obstetrics and gynecology: news, opinions, training. 2015;(3):80. (In Russ.) EDN: VNTCGD

[12]

Девятова Е.А., Цатурова К.А., Эсмурзиева З.И., и др. Миома матки // Акушерство и гинекология: новости, мнения, обучение. 2015. № 3(9). С. 80–90. EDN: VNTCGD

[13]

Kim HS, Baik JH, Pham LD, Jacobs MA. MR-guided high-intensity focused ultrasound treatment for symptomatic uterine leiomyomata. Acad Radiol. 2011;18(8):970–976. doi: 10.1016/j.acra.2011.03.008

[14]

Kim H.S., Baik J.H., Pham L.D., et al. MR-guided high-intensity focused ultrasound treatment for symptomatic uterine leiomyomata // Acad Radiol. 2011. Vol. 18, N. 8. P. 970–976. doi: 10.1016/j.acra.2011.03.008

[15]

Politova AK, Kira EF, Bolomatov NV, et al. Comparative evaluation of combined and isolated applications of high-intensity focused ultrasound and super-selective uterine artery embolization in treatment of patients with uterine fibroids. Journal of Obstetrics and Women’s Diseases. 2022;71(1):71–78. EDN: MREALK doi: 10.17816/JOWD71360

[16]

Политова А.К., Кира Е.Ф., Боломатов Н.В., и др. Сравнительная оценка результатов сочетанного и изолированного применения фокусированного ультразвука высокой интенсивности и суперселективной эмболизации маточных артерий в лечении больных миомой матки // Журнал акушерства и женских болезней. 2022. Т. 71, № 1. C. 71–78. EDN: MREALK doi: 10.17816/JOWD71360

RIGHTS & PERMISSIONS

Eсо-Vector

AI Summary AI Mindmap
PDF

129

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/