Efficacy of the different modes of insulin therapy in pregnant women with type 1 diabetes mellitus

Vladimir Vsevolodovoch Potin , Natalia Viktorovna Borovik , Alena Viktorovna Tiselko

Journal of obstetrics and women's diseases ›› 2013, Vol. 62 ›› Issue (3) : 77 -82.

PDF
Journal of obstetrics and women's diseases ›› 2013, Vol. 62 ›› Issue (3) : 77 -82. DOI: 10.17816/JOWD62377-82
Articles
oration

Efficacy of the different modes of insulin therapy in pregnant women with type 1 diabetes mellitus

Author information +
History +
PDF

Abstract

The article describes the principles of using the insulin pump therapy in patients with type 1 diabetes mellitus during pregnancy. There were obtained data about the state of the carbohydrate metabolism in pregnant women with type 1 diabetes using insulin pump therapy regimen (PI) and multiple daily insulin injections, the outcomes of pregnancy and labor.

Keywords

diabetes mellitus / pregnancy / pump therapy / multiple injections of insulin

Cite this article

Download citation ▾
Vladimir Vsevolodovoch Potin, Natalia Viktorovna Borovik, Alena Viktorovna Tiselko. Efficacy of the different modes of insulin therapy in pregnant women with type 1 diabetes mellitus. Journal of obstetrics and women's diseases, 2013, 62(3): 77-82 DOI:10.17816/JOWD62377-82

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Айламазян Э. К., Мозговая Е. В. Гестоз: теория и практика. — М.: МЕД пресс-информ, 2008. — 271 с.

[2]

Аржанова О.Н, Кошелева Н. Г. Особенности течения беременности и родов при сахарном диабете в современных условиях // Журнал акушерства и женских болезней. — 2006. — № 1. — С. 12–16.

[3]

Боровик Н. В., Аржанова О. Н. Влияние беременности на микрососудистые осложнения сахарного диабета // Журнал акушерства и женских болезней. — 2006. — № 2. — С. 10–13.

[4]

Выбор метода инсулинотерапии у беременных с сахарным диабетом 1-го типа / Демидова И. Ю., Игнатова Н. Г., Арбатская Н. Ю. [и др.] // Журнал акушерства и женских болезней. — 2011. — N 3. — С. 37–43.

[5]

Помповая инсулинотерапия сахарного диабета во время беременности / Потин В. В., Тиселько А. В., Боровик Н. В. [и др.] // Медицинский академический журнал. — 2008. — № 2. — С. 92–99.

[6]

Потин В. В., Боровик Н. В., Тиселько А. В. Сахарный диабет и репродуктивная система женщины // Журнал акушерства и женских болезней. — 2006. — № 1. — С. 86–90.

[7]

Continuous subcutaneous insulin infusion vs intensive conventional insulin therapy in pregnant diabetic women: a systematic review and metaanalysis of randomized, controlled trials / Mukhopadhyay A., Farrel T., Fraser R. [et al.] // Am. J. Obstet. Gynecol. — 2007. — Vol.197, N 5. — P. 447–456.

[8]

Effectiveness of continuous glucose monitoring in pregnant women with diabetes: randomised clinical trial / Murphy H., Rayman C., Lewis K. [et al.] // BMJ. — 2008. — Vol. 337. — P. 1680.

[9]

Fetal growthin women managed with insulin pump therapy compared to conventional insulin / Kernaghan D., Farrell T., Hammod P. [et al.] // Eur. J. Obstet. Gynecol. Reprod. Biol. — 2008. — Vol. 137. — P. 47–49.

[10]

Freinkel N. Banting Lecture 1980. Of pregnancy and progeny // Diabetes. — 1980. — Vol. 29. — P. 1023–1035.

[11]

Glycemic Variability: The Third сomponent of the Dysglycemia in Diabetes. Is It Important? How to Measure It? / Monnier L., Colette C., David R. [et al.] // J. Diabetes Sci. Technol. — 2008. — Vol. 2, N 6. — P. 1094–1100.

[12]

Kerssen A., de Valk H. W., Visser G. H. The Continuous Glucose Monitoring System during pregnancy of women with type 1 diabetes mellitus: accuracy assessment // Diabetes Technol Ther. — 2004. — Vol. 6, N 5. — P. 645–651.

[13]

Kerssen A., De Valk H.W, Visser G. H. Validation of the Continuous Glucose Monitoring System (CGMS) by the use of two CGMS simultaneously in pregnant women with type 1 diabetes mellitus // Diabetes Technol. Ther. — 2005. — Vol. 7, N 5. — P. 699–706.

[14]

Macrosomia in well controlled CSII treated Type I diabetic pregnancy / Cohen O., Keidar N., Simchen M. [et al.] // Gynecol. Endocrinol. — 2008. — Vol. 24, N 11. — P. 611–613.

[15]

Managing preexisting diabetes for pregnancy: summary of evidence and consensus recommendations for care / Kitzmiller J. L., Block J. M., Brown F. M. [et al.] // Diabetes Care. — 2008. — Vol. 31. — P. 1060–1079.

[16]

Maternal postprandial blood glucose levels and infant birth weight: the diabetes in early pregnancy study / Jovanovic-Peterson L., Peterson C. M., Reed G. F. [et al.] // Am. J. Obstet. Gynecol. — 1991. — Vol. 164. — P. 103.

[17]

Olinder A. L., Kernell A., Smide B. Missed bolus doses: devastating for metabolic control in CSII-treated adolescents with type 1 diabetes // Pediatr. Diabetes. — 2009. — Vol. 10. — P. 142–148.

[18]

Optimal timing for postprandial glucose measurement in pregnant women with diabetes and a non-diabetic pregnant population evaluated by the Continuous Glucose Monitoring System (CGMS) // Bühling K. J., Winkel T., Wolf C. [et al.] // J. Perinat. Med. — 2005. — Vol. 33. — P. 125–131.

[19]

Pankovska E., Blazik M. Bolus calculator with nutrition database software, a new concept of prandial insulin programming for pump users // J. Diabetes. Sci. Technol. — 2010. — Vol. 4, N 3. — P. 571–576.

[20]

Patterns of glycemia in normal pregnancy should the current therapeutic targets be challenged? / Hernandes T., Friedman J., VanPelt R. [et al.] // Diabetes Care. — 2011. — Vol.34, N 7. — P. 1660–1668.

[21]

Pickup J., Keen H. Continuous subcutaneous insulin infusion at 25 years: evidence base for the expanding use of insulin pump therapy in type 1 diabetes // Diabetes Care. — 2002. — Vol. 25, N 3. — P. 593–598.

[22]

Pickup J. C., Freeman S. C., Sutton A. J. Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data // BJM. — 2011. — Vol. 343.

[23]

Sensor-augmented pump therapy lowers HbA (1c) in suboptimally controlled Type 1 diabetes; a randomized controlled trial / Hermanides J., Nørgaard K., Bruttomesso D. [et al.] // Diabet Med. — 2011. — Vol. 28, N 10. — P. 1158–1167.

[24]

STAR 3 randomized controlled trial to compare sensor-augmented insulin pump therapy with multiple daily injections in the treatment of type 1 diabetes: research design, methods, and baseline characteristics of enrolled subjects / Davis S. N., Horton E. S., Battelino T. B. [et al.] // Diabetes Technol. Ther. — 2010. — Vol. 12, N 4. — P. 249–255.

[25]

The relationship between blood glucose excurtion and painful diabetic peripheral neuropathy: a pilot study / Oyibo S. O., Prasad Y. D. M., Jeckson N. J. [et al.] // Diabet Med. — 2002. — Vol. 19. — P. 870–873.

[26]

The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy: a randomised controlled trial / Battelino T., Conget I., Olsen B. [et al.] // Diabetologia. — 2012. — Vol. 55, N 12. — P. 3155–3162.

[27]

Wollitzer A. D., Zisser H., Jovanovic L. Insulin pumps and their use in pregnancy // Diabetes Technol Ther. — 2010. — Vol.12, suppl. 1. — P. S33–36.

RIGHTS & PERMISSIONS

Potin V.V., Borovik N.V., Tiselko A.V.

AI Summary AI Mindmap
PDF

143

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/