COMPARISON OF THE APPLICATION OF DOMESTIC «ELISA-IGM-DENGUE» KIT, DELIVERED IN THE D.I. IVANOVSKY INSTITUTE OF VIROLOGY (MOSCOW, RUSSIAN FEDERATION) AND «ANTI-DENGUE VIRUS ELISA IGM» KIT (EUROIMMUN, GERMANY) FOR THE SERODIAGNOSIS OF DENGUE FEVER

Yu. A Akinshina , V. F Larichev , M. A Saifullin , S. G Mardanly , A. M Butenko

Epidemiology and Infectious Diseases ›› 2017, Vol. 22 ›› Issue (1) : 4 -8.

PDF
Epidemiology and Infectious Diseases ›› 2017, Vol. 22 ›› Issue (1) : 4 -8. DOI: 10.17816/EID40949
Articles
research-article

COMPARISON OF THE APPLICATION OF DOMESTIC «ELISA-IGM-DENGUE» KIT, DELIVERED IN THE D.I. IVANOVSKY INSTITUTE OF VIROLOGY (MOSCOW, RUSSIAN FEDERATION) AND «ANTI-DENGUE VIRUS ELISA IGM» KIT (EUROIMMUN, GERMANY) FOR THE SERODIAGNOSIS OF DENGUE FEVER

Author information +
History +
PDF

Abstract

88 sera from patients with dengue fever were examined with the use of two test systems: Pilot Production kit «ELISA- IgM-dengue», delivered in the D.I. Ivanovsky Institute of Virology (Russian Federation) and. All 88 samples were positive for specific IgM in «ELISA-IgM-dengue», but 8 cases examined with the test kit «Anti-Dengue virus ELISA (IgM)» (Euroimmun, Germany) appeared to be negative. The ratio between the titers of anti-dengue IgM determined in patients’ blood samples by "ELISA-IgM-dengue" and «Ratio» (index, recommended by the company «Euroimmun» for differentiation of positive, equivocal or negative results, was evaluated. 53 blood sample containing M antibodies to cytomegalovirus (n = 43), Epstein-Barr virus (n = 6), herpes simplex virus (n = 2) and rubella virus (n = 2) were tested by both ELISA kits to compare their specificity. When «ELISA- IgM-dengue» kits were applied all observed samples were negative, but under the application of the «Anti-Dengue virus ELISA (IgM)» kit (Euroimmun, Germany) 17 samples (32.1%) were false positive or equivocal.

Keywords

dengue diagnosis / ELISA-IgM test kits / sensitivity and specificity

Cite this article

Download citation ▾
Yu. A Akinshina, V. F Larichev, M. A Saifullin, S. G Mardanly, A. M Butenko. COMPARISON OF THE APPLICATION OF DOMESTIC «ELISA-IGM-DENGUE» KIT, DELIVERED IN THE D.I. IVANOVSKY INSTITUTE OF VIROLOGY (MOSCOW, RUSSIAN FEDERATION) AND «ANTI-DENGUE VIRUS ELISA IGM» KIT (EUROIMMUN, GERMANY) FOR THE SERODIAGNOSIS OF DENGUE FEVER. Epidemiology and Infectious Diseases, 2017, 22(1): 4-8 DOI:10.17816/EID40949

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Vorndam V., Kuno G., Gubler D.J., Kuno G. Dengue Anddengue Hemorrhagic Fever. New York: CAB International. Laboratory Diagnosis of Dengue Virus Infections; 1997: 313-33.

[2]

Guzman M.G., Kouri G. Advances in dengue diagnosis. J. Clin. Diagn. Lab. Immunol. 1996; 3: 621-7.

[3]

Dengue: Guidelines for Diagnosis, Treatment, Prevention and Control. New Edition. WHO; 2009.

[4]

Bundo K., Igarashi A. Antibody-capture ELISA for detection of immunoglobulin M antibodies in sera from Japanese encephalitis and dengue hemorrhagic fever patients. J. Virol. Meth. 1985; 11 (1): 15-22.

[5]

Martin D.A., Muth D.J., Brown T., Johnson A.J., Karabatsos N., Roehrig J. T. Standardization of immunoglobulin M capture enzyme-linked immunosorbent assays for routine diagnosis of arboviral infections. Clin. Microbiol. 2000; 38: 1823-36.

[6]

Meegan J.M., LeDuc J.W. Enzyme immunoassay. In: Manual of Hemorrhagic Fever with Renal Syndrome / Eds Ho Wang Lee, J.M. Dalrymple. WHO Collaborating Center for Virus Referece and Research (HFRS). Institute for viral Diseases, Korea University. Seoul; 1989: 83-7.

[7]

Kuno G., Gomez I., Gubler D.J. An ELISA procedure for the diagnosis of dengue infections. J. Virol. Meth. 1991; 33: 102-13.

[8]

Ларичев В.Ф., Сайфуллин М.А., Акиншина Ю.А., Хуторецкая Н.В., Бутенко А.М. Завозные случаи арбовирусных инфекций в Российской Федерации. Эпидемиол. и инфекц. бол. 2012; (1): 35-9.

RIGHTS & PERMISSIONS

Eco-vector

AI Summary AI Mindmap
PDF

130

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/