Serum markers for immunological response to metal alloys of endoprostheses

Svetlana N. Shatokhina , Vadim V. Zar , Mikhail V. Zar , Vladimir Nikolaevich Shabalin

N.N. Priorov Journal of Traumatology and Orthopedics ›› 2020, Vol. 27 ›› Issue (2) : 30 -34.

PDF
N.N. Priorov Journal of Traumatology and Orthopedics ›› 2020, Vol. 27 ›› Issue (2) : 30 -34. DOI: 10.17816/vto202027230-34
Original study articles
research-article

Serum markers for immunological response to metal alloys of endoprostheses

Author information +
History +
PDF

Abstract

A study of solid-phase structures of blood serum using wedge-shaped and marginal dehydration methods (Litos system technology) was conducted in order to find out the causes of an inflammatory reaction followed by fibrosis in the second operated joint in a patient with bilateral knee arthritis. The study was aimed at identifying specific morphological markers that characterize the body’s response to the endoprosthesis material. Its solid-phase structures indicated the activation of a hyperergic reaction with daily incubation of blood serum with an alloy of titanium, aluminum, and vanadium. On the contrary, the immunological activity of blood serum can be suppressed and the structures present in it can be transformed into amorphous detritus with the incubation of an alloy of cobalt, chromium, and molybdenum. It was observed from the study that the nature of the immunological reaction of a sensitized organism depends on the type of metals that are part of the endoprosthesis. The immune response causes inflammation of the periarticular tissue, followed by its fibrosation and the formation of a scar demarcation shell that separates the periarticular tissue from the endoprosthesis and performs the function of an immunological barrier on the alloy of titanium, aluminum, and vanadium. On the other hand, an immunological reaction causes the destruction of inflamed periarticular tissue, followed by gradual destruction of the articular bag on the alloy of cobalt, chromium, and molybdenum.

Keywords

metal alloys of endoprostheses / immunological rejection of the endoprosthesis / serum markers

Cite this article

Download citation ▾
Svetlana N. Shatokhina, Vadim V. Zar, Mikhail V. Zar, Vladimir Nikolaevich Shabalin. Serum markers for immunological response to metal alloys of endoprostheses. N.N. Priorov Journal of Traumatology and Orthopedics, 2020, 27(2): 30-34 DOI:10.17816/vto202027230-34

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Hallab N, Merritt K, Jacobs JJ. Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am. 2001;83(3):428-436. https://doi.org/10.2106/00004623-200103000-00017.

[2]

Granchi D, Cenni E, Giunti A, Baldini N. Metal hypersensitivity testing in patients undergoing joint replacement: a systematic review. J Bone Joint Surg Br. 2012;94(8):1126-1134. https://doi.org/10.1302/0301-620X.94B8.28135.

[3]

Thakur RR, Ast MP, McGraw M, Bostrom MP, Rodriguez JA, Parks ML. Severe persistent synovitis after cobalt-chromium total knee arthroplasty requiring revision. Orthopedics. 2013;36(4):e520-e524. https://doi.org/10.3928/01477447-20130327-34.

[4]

Шабалин В.Н., Шатохина С.Н. Функциональная морфология неклеточных тканей человека. М.: РАН; 2019. 356 c. [Shabalin VN, Shatokhina SN. Funktsional’naya morfologiya nekletochnykh tkanei cheloveka. Moscow: RAN; 2019. 356 p. (In Russ.).]

[5]

Шатохина С.Н., Шабалин В.Н. Атлас структур неклеточных тканей человека в норме и патологии. Т. 2. Морфологические структуры сыворотки крови. Тверь: Триада; 2013. C. 74-87. [Shatokhina SN, Shabalin VN. Atlas struktur nekletochnykh tkanei cheloveka v norme i patologii. Vol. 2. Morfologicheskie struktury syvorotki krovi. Tver: Triada; 2013. P. 74-87. (In Russ.).]