Comparative evaluation of corrected orthogonal and 12 conventional ECG leads in the diagnosis of ventricular hypertrophy in children
L. A. Chuchelina
Kazan medical journal ›› 1981, Vol. 62 ›› Issue (3) : 35 -39.
Comparative evaluation of corrected orthogonal and 12 conventional ECG leads in the diagnosis of ventricular hypertrophy in children
Using corrected orthogonal (ECG system Frank and 12 conventional leads, 525 children were examined: 300 healthy children, 125 with heart defects leading to right ventricular hypertrophy, and 100 with breeds leading to left ventricular hypertrophy. Criteria for diagnosing hypertrophy of the right and left ventricles were developed. heart in children 3-7 and 8-15 years old Comparative analysis of the results indicates a higher sensitivity of the Frank system compared with 12 conventional leads in identifying left ventricular hypertrophy in children.
ventricular hypertrophy / ECG / corrected orthogonal leads
| [1] |
Озол Э.А. Корригированные ортогональные отведения электрокардиограммой в анализе биоэлектрической активности сердца. Автореф. докт. дисс., Казань, 1972 |
| [2] |
Середа Г.Е. Электрокардиографические критерии гипертрофии желудочков при пороках сердца у детей. Автореф. канд. дисс., М , 1973 |
| [3] |
Мумджиев H.X. (Болгария). Сравнительна оценка на обичайната и ортогоналната электрокардиографиски системи приложени при деца-здрави ис камерно обременяваие: Автореф. на дис,. труд за присъждане на научно степен «кандидат медицинските науки». Пловдив, 1975 |
| [4] |
Shakibi J.G., Siassi B., Агуanpur J., Paydar M. J. Electrocardiol., 1976, 9, 1 |