Abstract

Aim. Assessment of the impact of independent ultrasound screening by the emergency physician on the daily activities of the emergency department.

Methods. The effectiveness of the use of ultrasound screening by the emergency physician was assessed using computer-based simulation modeling and the subsequent implementation of the data obtained into the practical work of the emergency department. The results were analyzed using descriptive statistical methods.

Results. In the course of the study, a simulated model of emergency department was built, similar to the actually functioning department in the Pavlov First St. Petersburg State Medical University. The new professional emergency physician’s standard, requiring knowing the basics of ultrasound-based diagnosis, were implemented first in the model and then in everyday practice. Independent ultrasound screening by the emergency physician allows reducing the length of stay of patients in the emergency department and the workload on medical personnel at the same time increasing the capacity of the department which is confirmed both by computer simulation and by actual implementation in the daily activities of the department.

Conclusion. The data received are indicative of a positive impact of independent ultrasound screening on the hospital stay of patients in the department and workload on the medical staff; emergency residency program should be complemented by teaching the basics of ultrasound diagnosis.

Keywords

emergency department / simulation modeling / ultrasound screening

Cite this article

Download citation ▾
V M Teplov, E A Tsebrovskaya, V V Kolomoytsev, E A Karpova, I P Minnulin, S F Bagnenko. Ultrasound-based diagnosis by the physician of emergency department: simulation modeling and practical implementation. Kazan medical journal, 2019, 100(3): 488-491 DOI:10.17816/KMJ2019-488

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Bagnenko S.F., Miroshnichenko A.G., Polushin Yu.S. et al. Organizatsiya raboty statsionarnogo otdeleniya skoroy meditsinskoy pomoshchi. (Organization of the in-patient emergency department service.) Moscow: GEOTAR-Media, 2015; 80 р. (In Russ.)

[2]

Багненко С.Ф., Мирошниченко А.Г., Полушин Ю.С. и др. Организация работы стационарного отделения скорой медицинской помощи. М.: ГЭОТАР-Медиа. 2015; 80 с.

[3]

Prefessional standard for the ambulance doctor adopted by the Ministry of Labour and Social Protection of the Russian Federation on 14th of March, 2018 №133n. (In Russ.)

[4]

Профессиональный стандарт врача скорой медицинской помощи, утверждённый приказом Министерства труда и социальной защиты Российской Федерации от 14 марта 2018 года №133н.

[5]

Hansen W., Mitchell C.E., Bhattarai B. et al. Perception of point-of-care ultrasound performed by emergency medicine physicians. J. Clin. Ultrasound. 2017; 45 (7): 408–415. DOI: 10.1002/jcu.22443.

[6]

Wilson S.P., Connolly K., Lahham S. et al. Point-of-care ultrasound versus radiology department pelvic ultrasound on emergency department length of stay. World J. Emerg. Med. 2016; 7 (3): 178–182. DOI: 10.5847/wjem.j.1920-8642.2016.03.003.

[7]

Kulikova O.M., Ovsyannikov N.V., Lyapin V.A. Simulation of the performance of medical institutions in the example of Omsk. Nauka o cheloveke: gumanitarnyye issledovaniya. 2014; (4): 219–225. (In Russ.)

[8]

Куликова О.М., Овсянников Н.В., Ляпин В.А. Имитационное моделирование деятельности медицинских учреждений на примере Омска. Наука о человеке: гуманитарные исследования. 2014; (4): 219–225.

[9]

Yakimov I.M., Kirpichnikov A.P. Simulation of probability objects in FlexSim system. Vestnik tekhnologicheskogo universiteta. 2016; 19 (21): 170–173. (In Russ.)

[10]

Якимов И.М., Кирпичников А.П. Имитационное моделирование вероятностных объектов в системе Flexsim. Вестн. технол. ун-та. 2016; 19 (21): 170–173.

[11]

Pal'mov S.V., Zhuykova A.A Review of possibilities of flexsim imitation modeling system in healthcare. Mezhdunarodnyy nauchno-issledovatel'skiy zhurnal. 2018; (1): ­124–127. (In Russ.)

[12]

Пальмов С.В., Жуйкова А.А Обзор возможностей системы имитационного моделирования Flexsim в сфере здравоохранения. Международ. науч.-исслед. ж. 2018; (1): 124–127. DOI: 10.23670/IRJ.2018.67.082.

[13]

https://healthcare.flexsim.com/whats-new-flexsim-hc/ (access date: 01.02.2019).

[14]

Whitson M.R., Mayo P.H. Ultrasonography in the emergency department. Crit. Care. 2016; 20 (1): 227. DOI: 10.1186/s13054-016-1399-x.

[15]

Nicola R., Dogra V. Ultrasound: the triage tool in the emergency department: using ultrasound first. Br. J. Radiol. 2016; 89 (1061): 20150790. DOI: 10.1259/bjr.20150790.

[16]

Zhang S., Zhu D., Wan Z. et al. Utility of point-of-care ultrasound in acute management triage of earthquake injury. Am. J. Emerg. Med. 2014; 32: 92–95. DOI: 10.1016/j.ajem.2013.10.009.

[17]

Bagnenko S.F., Teplov V.M., Miroshnichenko A.G. et al. Experience of using of pocket-sized visualization tool in emergency department. Skoraya meditsinskaya pomoshch'. 2017; (2): ­69–72. (In Russ.)

[18]

Багненко С.Ф., Теплов В.М., Мирошниченко А.Г. и др. Опыт применения портативного ультразвукового сканера в работе стационарного отделения скорой медицинской помощи. Скорая мед. помощь. 2017; (2): 69–72. DOI: 10.24884/2072-6716-2017-18-2-69-72.

RIGHTS & PERMISSIONS

Teplov V.M., Tsebrovskaya E.A., Kolomoytsev V.V., Karpova E.A., Minnulin I.P., Bagnenko S.F.

AI Summary AI Mindmap
PDF

120

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/