Integrated Ion and Neutral Particle Analyzer for Chinese Mars Mission

Journal of Deep Space Exploration ›› 2019, Vol. 6 ›› Issue (2) : 142 -149.

PDF (4894KB)
Journal of Deep Space Exploration ›› 2019, Vol. 6 ›› Issue (2) : 142 -149. DOI: 10.15982/j.issn.2095-7777.2019.02.005
Topic:Deep Space Environment Exploration
Topic:Deep Space Environment Exploration

Integrated Ion and Neutral Particle Analyzer for Chinese Mars Mission

Author information +
History +
PDF (4894KB)

Abstract

The miniature and integrated design is a main trend in science payload development for deep space. An integrated ion and neutral particle analyzer is built for Chinese Mars exploration project. The measurements of ion and energetic neutral atom share the sensor and electronics and are integrated in a single instrument with lower mass and power. Electrostatic analyzing method is used to measure the ions'energy and direction. Time of flight method is used to measure the ions species. The energetic neutral atoms are ionized firstly and the same measurement method with ions. The qualification model is calibrated and the results fulfill the requirements for the Mars project.

Keywords

integrated design / Mars / ion / energetic neutral atom / analyzer

Cite this article

Download citation ▾
null. Integrated Ion and Neutral Particle Analyzer for Chinese Mars Mission. Journal of Deep Space Exploration, 2019, 6(2): 142-149 DOI:10.15982/j.issn.2095-7777.2019.02.005