Research articles

Study on a 60?kV/5?A magnetron injection gun for 200?GHz electron cyclotron master

Expand
  • THz Research Center, School of Physical Electronics, University of Electronic Science and Technology of China, Chengdu 610054, China;

Published date: 05 Dec 2009

Abstract

To develop 200GHz electron cyclotron maser (ECM) in University of Electronic Science and Technology of China, a magnetron injection gun (MIG) with 60kV/5A has been designed. The behavior of the designed magnetron injection gun with variations of relevant parameters is given in detail by means of computer simulations. The preliminary and operation parameters of the gun are reported. The optimization by using the EGUN code shows that the ratio of the perpendicular velocity to the parallel velocity of the electron beam is 1.63, and the perpendicular and parallel velocities spread are 2.62% and 6.63%, respectively.

Cite this article

Wenjie FU, Yang YAN, Shenggang LIU, . Study on a 60?kV/5?A magnetron injection gun for 200?GHz electron cyclotron master[J]. Frontiers of Electrical and Electronic Engineering, 2009 , 4(4) : 440 -445 . DOI: 10.1007/s11460-009-0061-7