An image reconstruction algorithm of EIT based on pulmonary prior information
Published date: 05 Jun 2009
Copyright
Using a CT scan of the pulmonary tissue, a human pulmonary model is established combined with the structure property of the human lung tissue using the software COMSOL. Combined with the conductivity contribution information of the human tissue and organ, an image reconstruction method of electrical impedance tomography based on pulmonary prior information is proposed using the conjugate gradient method. Simulation results show that the uniformity index of sensitivity distribution of the pulmonary model is 15.568, which is significantly reduced compared with 34.218 based on the round field. The proposed algorithm improves the uniformity of the sensing field, the image resolution of the conductivity distribution of pulmonary tissue and the quality of the reconstruction image based on pulmonary prior information.
Huaxiang WANG , Li HU , Jing WANG , Lu LI . An image reconstruction algorithm of EIT based on pulmonary prior information[J]. Frontiers of Electrical and Electronic Engineering, 2009 , 4(2) : 121 -126 . DOI: 10.1007/s11460-009-0020-3
1 |
Wang H X, Wang C Y. Pulmonary electrical impedance tomography system. Chinese Medical Equipment Journal, 2006, 27(4): 3-4 (in Chinese)
|
2 |
Wang H, Gao J B, Luo J P. Review of electrical impedance tomography. Beijing Biomedical Engineering, 2006, 25(2): 209-212 (in Chinese)
|
3 |
Bi D X. Electro-magnetic Field Theory. Beijing: Publishing House of Electronics Industry, 1985 (in Chinese)
|
4 |
Polydorides N, McCann H. Electrode configurations for improved spatial resolution in electrical impedance tomography. Measurement Science and Technology, 2002, 13(12): 1862-1870
|
5 |
Feng C Z, Ma X K. An Introduction to Engineering Electromagnetic Fields. Beijing: Higher Education Press, 2000 (in Chinese)
|
6 |
Dehghani H, Barber D C, Basarab-Horwath I. Incorporating a priori anatomical information into image reconstruction in electrical impedance tomography. Physiological Measurement, 1999, 20(1): 87-102
|
7 |
Polydorides N, Lionheart W R B. A Matlab toolkit for three-dimensional electrical impedance tomography: a contribution to the electrical impedance and diffuse optical reconstruction software project. Measurement Science and Technology. 2002, 13(12): 1871-1883
|
8 |
Hu L, Wang H X, Zhao B, Yang W Q. A hybrid reconstruction algorithm for electrical impedance tomography. Measurement Science and Technology, 2007, 18(3): 813-818
|
9 |
Wang H X, Zhang L F, Zhu X M. Optimum design of array electrode for ECT system. Journal of Tianjin University, 2003, 36(3): 307-310 (in Chinese)
|
10 |
Xie C G, Plaskowski A, Beck M S. 8-electrode capacitance system for two-component flow identification, Part I: tomographic flow imaging. IEE Proceedings A – Science, Measurement and Technology, 1989, 136(4): 173-183
|
11 |
Kauppinen P, Hyttinen J, Malmivuo J. Sensitivity distribution simulations of impedance tomography electrode combinations. International Journal of Bioelectromagnetism, 2005, 7(1): 344-347
|
/
〈 |
|
〉 |