Fast removal of ocular artifacts from electroencephalogram signals using spatial constraint independent component analysis based recursive least squares in brain-computer interface

Bang-hua YANG, Liang-fei HE, Lin LIN, Qian WANG

PDF(780 KB)
PDF(780 KB)
Front. Inform. Technol. Electron. Eng ›› 2015, Vol. 16 ›› Issue (6) : 486-496. DOI: 10.1631/FITEE.1400299

Fast removal of ocular artifacts from electroencephalogram signals using spatial constraint independent component analysis based recursive least squares in brain-computer interface

Author information +
History +

Abstract

Ocular artifacts cause the main interfering signals within electroencephalogram (EEG) signal measurements. An adaptive filter based on reference signals from an electrooculogram (EOG) can reduce ocular interference, but collecting EOG signals during a long-term EEG recording is inconvenient and uncomfortable for the subject. To remove ocular artifacts from EEG in brain-computer interfaces (BCIs), a method named spatial constraint independent component analysis based recursive least squares (SCICA-RLS) is proposed. The method consists of two stages. In the first stage, independent component analysis (ICA) is used to decompose multiple EEG channels into an equal number of independent components (ICs). Ocular ICs are identified by an automatic artifact detection method based on kurtosis. Then empirical mode decomposition (EMD) is employed to remove any cerebral activity from the identified ocular ICs to obtain exact artifact ICs. In the second stage, first, SCICA applies exact artifact ICs obtained in the first stage as a constraint to extract artifact ICs from the given EEG signal. These extracted ICs are called spatial constraint ICs (SC-ICs). Then the RLS based adaptive filter uses SC-ICs as reference signals to reduce interference, which avoids the need for parallel EOG recordings. In addition, the proposed method has the ability of fast computation as it is not necessary for SCICA to identify all ICs like ICA. Based on the EEG data recorded from seven subjects, the new approach can lead to average classification accuracies of 3.3% and 12.6% higher than those of the standard ICA and raw EEG, respectively. In addition, the proposed method has 83.5% and 83.8% reduction in time-consumption compared with the standard ICA and ICA-RLS, respectively, which demonstrates a better and faster OA reduction.

Keywords

Ocular artifacts / Electroencephalogram (EEG) / Electrooculogram (EOG) / Brain-computer interface (BCI) / Spatial constraint independent component analysis based recursive least squares (SCICA-RLS)

Cite this article

Download citation ▾
Bang-hua YANG, Liang-fei HE, Lin LIN, Qian WANG. Fast removal of ocular artifacts from electroencephalogram signals using spatial constraint independent component analysis based recursive least squares in brain-computer interface. Front. Inform. Technol. Electron. Eng, 2015, 16(6): 486‒496 https://doi.org/10.1631/FITEE.1400299

References

[1]
Akhtar, M.T., Mitsuhashi, W., James, C.J., 2012. Employing spatially constrained ICA and wavelet denoising, for automatic removal of artifacts from multichannel EEG data. Signal Process., 92(2): 401-416. [
CrossRef Google scholar
[2]
Arasteh, A., Janghorbani, A., Moradi, M.H., 2010. A survey on EMD sensitivity to SNR for EEG feature extraction in BCI application. Proc. 5th Cairo Int. Biomedical Engineering Conf., p.175-179. [
CrossRef Google scholar
[3]
Barbati, G., Porcaro, C., Zappasodi, P., , 2004. Optimization of an independent component analysis approach for artifact identification and removal in magnetoencephalographic signals. Clin. Neurophysiol., 115(5): 1220-1232. [
CrossRef Google scholar
[4]
Blankertz, B., Dornhege, G., Krauledat, M., , 2007. The non-invasive Berlin brain-computer interface: fast acquisition of effective performance in untrained subjects. NeuroImage, 37(2): 539-550.
[5]
Chan, H.L., Tsai, Y.T., Meng, L.F., , 2010. The removal of ocular artifacts from EEG signals using adaptive filters based on ocular source components. Ann. Biomed. Eng., 38(11): 3489-3499. [
CrossRef Google scholar
[6]
Delorme, A., Sejnowski, T., Makeig, S., 2007. Enhanced detection of artifacts in EEG data using higher-order statistics and independent component analysis. NeuroImage, 34(4): 1443-1449. [
CrossRef Google scholar
[7]
Güçlü, U., Güçlütürk, Y., Loo, C.K., 2011. Evaluation of fractal dimension estimation methods for feature extraction in motor imagery based brain computer interface. Procedia Comput. Sci., 3: 589-594. [
CrossRef Google scholar
[8]
Hazra, B., Roffel, A., Narasimhan, S., , 2010. Modified cross-correlation method for the blind identification of structures. J. Eng. Mech., 136(7): 889-897. [
CrossRef Google scholar
[9]
He, P., Wilson, G., Russell, C., 2004. Removal of ocular artifacts from electroencephalogram by adaptive filtering. Med. Biol. Eng. Comput, 42(3): 407-412. [
CrossRef Google scholar
[10]
Hesse, C.W., James, C.J., 2005. The FastICA algorithm with spatial constraints. IEEE Signal Process. Lett., 12(11): 792-795. [
CrossRef Google scholar
[11]
Huang, L., Wang, H., 2013. Reducing the computation time for BCI using improved ICA algorithms. Proc. 10th Int. Symp. on Neural Networks, p.299-304. [
CrossRef Google scholar
[12]
Jung, T.P., Makeig, S., Humphries, C., , 2000. Removing electroencephalographic artifacts by blind source separation. Psychophysiology, 37(2): 163-178. [
CrossRef Google scholar
[13]
Klados, M.A., Bratsas, C., Frantzidis, C., , 2010. A kurtosis-based automatic system using naïve Bayesian classifier to identity ICA components contaminated by EOG or ECG artifacts. Proc. XII Mediterranean Conf. on Medical and Biological Engineering and Computing, p.49-52. [
CrossRef Google scholar
[14]
Li, X., Wang, W.B., 2013. Studying on denoising of chaotic signal using ICA and EMD. Proc. Int. Symp. on Geo-Informatics in Resource Management and Sustainable Ecosystem, p.564-572. [
CrossRef Google scholar
[15]
Li, Y., Koike, Y.H., 2012. A real-time BCI with a small number of channels based on CSP. Neur. Comput. Appl., 20(8): 1187-1192. [
CrossRef Google scholar
[16]
Mammone, N., Inuso, G., La Foresta, F., , 2007. Multiresolution ICA for artifact identification from electroencephalographic recordings. Proc. 11th Int. Conf. on Neural Networks, p.680-687. [
CrossRef Google scholar
[17]
Nguyen, H.A.T., Musson, J., Li, F., , 2012. EOG artifact removal using a wavelet neural network. Neurocomputing, 97: 374-389. [
CrossRef Google scholar
[18]
Qiao, X., Li, D., Dong, Y., 2009. P300 feature extraction based on parametric model and FastICA algorithm. Proc. 5th Int. Conf. on Natural Computation, p.585-589. [
CrossRef Google scholar
[19]
Wang, B., 2010. Comprehensive Study on Removal of Artifacts from EEG Data. MS Thesis, Zhejiang University, Hangzhou, China (in Chinese).
[20]
Winkler, I., Brandl, S., Horn, F., , 2014. Robust artifactual independent component classification for BCI practitioners. J. Neur. Eng., 11(3): 035013.1-035013.10. [
CrossRef Google scholar
[21]
Xu, H., Song, W., Hu, Z.P., , 2010. A speedup SVM decision method for online EEG processing in motor imagery BCI. Proc. 10th Int. Conf. on Intelligent Systems Design and Applications, p.149-154. [
CrossRef Google scholar
[22]
Yang, B.H., Yan, G.Z., Wu, T., , 2007. Subject-based feature extraction using fuzzy wavelet packet in braincomputer interfaces. Signal Process., 87(7): 1569-1574. [
CrossRef Google scholar
PDF(780 KB)

Accesses

Citations

Detail

Sections
Recommended

/