Effect of database, pre-processing pipeline, and scan duration on rs-fMRI functional connectivity based treatment targets for TMS obtained using the Stanford Neuromodulation Therapy (SNT) protocol

Lian Yu , Xue Li , Neil Roberts , Xiaoqi Huang , Haoyang Xing

Psychoradiology ›› 2026, Vol. 6 ›› Issue (1) : kkag024

PDF
Psychoradiology ›› 2026, Vol. 6 ›› Issue (1) :kkag024 DOI: 10.1093/psyrad/kkag024
Research Article
research-article
Effect of database, pre-processing pipeline, and scan duration on rs-fMRI functional connectivity based treatment targets for TMS obtained using the Stanford Neuromodulation Therapy (SNT) protocol
Author information +
History +
PDF

Abstract

Background Transcranial Magnetic Stimulation targeting the dorsolateral prefrontal cortex (DLPFC) is a therapeutic approach for treating depressive disorder. However, traditional anatomical methods often fail to localize a treatment target. The functional connectivity method represented by the Stanford Neuromodulation Therapy (SNT) has been proposed and demonstrated efficacy. A step of SNT is to achieve DLPFC target localization using resting-state functional magnetic resonance imaging (rs-fMRI) data, based on measurement of the negative correlation coefficient between the functional connectivity of DLPFC and the subgenual anterior cingulate cortex (sgACC).

Methods This study has three goals. Firstly, to apply the SNT protocol to investigate variability in target localization in four groups (Human Connectome Project [HCP], China Human Connectome Project [CHCP], major depressive disorder [MDD] from Huaxi Depression Imaging Cohort Study [HX-DICS], and healthy controls [HC] from HX-DICS) from three databases. Secondly, to investigate potential differences in how the DPABI and FSL rs-fMRI pre-processing pipelines, particularly the spatial smoothing, denoising, and temporal filtering steps, affect the localization of individualized DLPFC targets. Thirdly, to assess the effect of rs-fMRI scan duration (ranging from 6 to 30 min) on target localization.

Results Significant inter-subject variability in DLPFC coordinates was found, emphasizing the necessity of individualized targeting. DPABI and FSL pre-processing produced significant differences in target coordinates, which exceeded 1 cm, with mean Euclidean distances ranging from 1.45 to 3.82 cm across cohorts, and individual maximum deviations reaching 6.14 cm. FSL pipeline consistently produced higher negative correlation coefficients than DPABI. Scan duration analysis indicated that after 12 min, the stability of individual target positions no longer improved significantly with prolonged scanning time, suggesting that approximately 12 min may provide sufficiently reliable data for target computation.

Conclusion Taken together, findings demonstrate that advancing precision neuromodulation therapy requires optimized data acquisition, standardized workflows, software-specific validation, and optimum scan duration.

Keywords

major depressive disorder (MDD) / pre-processing pipeline / personalized treatment target / scan duration / Stanford Neuromodulation Therapy (SNT) / transcranial magnetic stimulation (TMS)

Cite this article

Download citation ▾
Lian Yu, Xue Li, Neil Roberts, Xiaoqi Huang, Haoyang Xing. Effect of database, pre-processing pipeline, and scan duration on rs-fMRI functional connectivity based treatment targets for TMS obtained using the Stanford Neuromodulation Therapy (SNT) protocol. Psychoradiology, 2026, 6 (1) : kkag024 DOI:10.1093/psyrad/kkag024

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Beam W, Borckardt JJ, Reeves ST, et al. (2009) An efficient and accurate new method for locating the F3 position for prefrontal TMS applications. Brain Stimul 2(1): 50-4.

[2]

Berlim MT, van den Eynde F, Tovar-Perdomo S, et al. (2014) Response, remission and drop-out rates following high-frequency repetitive transcranial magnetic stimulation (rTMS) for treating major depression: a systematic review and meta-analysis of randomized, double-blind and sham-controlled trials. Psychol Med 44(2): 225-39.

[3]

Birn RM, Molloy EK, Patriat R, et al. (2013) The effect of scan length on the reliability of resting-state fMRI connectivity estimates. Neuroimage 83: 550-8.

[4]

Botvinik-Nezer R, Holzmeister F, Camerer CF, et al. (2020) Variability in the analysis of a single neuroimaging dataset by many teams. Nature 582(7810): 84-8.

[5]

Bowring A, Maumet C, Nichols TE (2019) Exploring the impact of analysis software on task fMRI results. Hum Brain Mapp 40(11): 3362-84.

[6]

Caulfield KA, Fleischmann HH, Cox CE, et al. (2022) Neuronavigation maximizes accuracy and precision in TMS positioning: evidence from 11,230 distance, angle, and electric field modeling measurements. Brain Stimul 15(5): 1192-205.

[7]

Chen J, Zhang Y, Liu S, et al. (2025) Neural-genetic-environmental evidence for a disease factor in mental and physical health multimorbidity. Nat Commun 16: 65055.

[8]

Cole EJ, Phillips AL, Bentzley BS, et al. (2022) Stanford Neuromodulation Therapy (SNT): a double-blind randomized controlled trial. AJP 179(2): 132-41.

[9]

Cole EJ, Stimpson KH, Bentzley BS, et al. (2020) Stanford accelerated intelligent neuromodulation therapy for treatment-resistant depression. AJP 177(8): 716-26.

[10]

Conca A, Peschina W, König P, et al. (2002) Effect of chronic repetitive transcranial magnetic stimulation on regional cerebral blood flow and regional cerebral glucose uptake in drug treatment-resistant depressives. Neuropsychobiology 45: 27-31.

[11]

Deng ZD, Lisanby SH, Peterchev AV (2013) Electric field depth-focality tradeoff in transcranial magnetic stimulation: simulation comparison of 50 coil designs. Brain Stimul 6(1): 1-13.

[12]

Eshel N, Keller CJ, Wu W, et al. (2020) Global connectivity and local excitability changes underlie antidepressant effects of repetitive transcranial magnetic stimulation. Neuropsychopharmacol 45(6): 1018-25.

[13]

Fan J, Tso IF, Maixner DF, et al. (2019) Segregation of salience network predicts treatment response of depression to repetitive transcranial magnetic stimulation. NeuroImage Clin 22: 101719.

[14]

Ge J, Yang G, Han M, et al. (2023) Increasing diversity in connectomics with the Chinese Human Connectome Project. Nat Neurosci 26: 163-72.

[15]

Hansen PEB, Ravnkilde B, Videbech P, et al. (2011) Low-frequency repetitive transcranial magnetic stimulation inferior to electroconvulsive therapy in treating depression. J ECT 27(1): 26-32.

[16]

He H, Hong L, Sajda P (2023) Pupillary response is associated with the reset and switching of functional brain networks during salience processing. PLoS Comput Biol 19(5): e1011081.

[17]

Herwig U, Padberg F, Unger J, et al. (2001) Transcranial magnetic stimulation in therapy studies: examination of the reliability of “standard” coil positioning by neuronavigation. Biol Psychiatry 50(1): 58-61.

[18]

Höflich G, Kasper S, Hufnagel A, et al. (1993) Application of transcranial magnetic stimulation in treatment of drug-resistant major depression-a report of two cases. Hum Psychopharmacol 8: 361-5.

[19]

Jenkinson M, Beckmann CF, Behrens TEJ, et al. (2012) FSL. Neuroimage 62(2): 782-90.

[20]

Liu G, Li J, Zhao J, et al. (2023) Transcranial magnetic stimulation (TMS) localization by co-registration of facial point clouds. Brain Stimul 16(1): 79-81.

[21]

Ma L, Braun SE, Steinberg JL, et al. (2024) Effect of scanning duration and sample size on reliability in resting state fMRI dynamic causal modeling analysis. Neuroimage 292: 120604.

[22]

Morriss R, Briley PM, Webster L, et al. (2024) Connectivity-guided intermittent theta burst versus repetitive transcranial magnetic stimulation for treatment-resistant depression: a randomized controlled trial. Nat Med 30(2): 403-13.

[23]

Notzon S, Steinberg C, Zwanzger P, et al. (2018) Modulating emotion perception: opposing effects of inhibitory and excitatory prefrontal cortex stimulation. Biol Psychiatry Cogn Neurosci Neuroimaging 3(4): 329-36.

[24]

Pascual-Leone A, Hallett M (1994) Induction of errors in a delayed response task by repetitive transcranial magnetic stimulation of the dorsolateral prefrontal cortex. Neuroreport 5(18): 2517-20.

[25]

Pauli R, Bowring A, Reynolds R, et al. (2016) Exploring fMRI results space: 31 variants of an fMRI analysis in AFNI, FSL, and SPM. Front Neuroinform 10: 24.

[26]

Popescu V, Schoonheim MM, Versteeg A, et al. (2016) Grey matter atrophy in multiple sclerosis: clinical interpretation depends on choice of analysis method. PLoS One 11(1): e0143942.

[27]

Siddiqi SH, Taylor SF, Cooke D, et al. (2020) Distinct symptom-specific treatment targets for circuit-based neuromodulation. AJP 177(5): 435-46.

[28]

Smith SM, Beckmann CF, Ramnani N, et al. (2005) Variability in fMRI: a re-examination of inter-session differences. Hum Brain Mapp 24(3): 248-57.

[29]

Taïb S, Arbus C, Sauvaget A, et al. (2018) How does repetitive transcranial magnetic stimulation influence the brain in depressive disorders?: a review of neuroimaging Magnetic resonance imaging studies. J ECT 34(2): 79-86.

[30]

Tang Y, Zhao L, Lou Y, et al. (2018) Brain structure differences between Chinese and Caucasian cohorts: a comprehensive morphometry study. Hum Brain Mapp 39(5): 2147-55.

[31]

Trapp NT, Bruss J, King Johnson M, et al. (2020) Reliability of targeting methods in TMS for depression: beam F3 vs. 5.5 cm. Brain Stimul 13(3): 578-81.

[32]

Van Dijk KR, Hedden T, Venkataraman A, et al. (2010) Intrinsic functional connectivity as a tool for human connectomics: theory, properties, and optimization. J Neurophysiol 103(1): 297-321.

[33]

Vasileiadi M, Woletz M, Linhardt D, et al. (2023) Improved brain stimulation targeting by optimising image acquisition parameters. Neuroimage 276: 120175.

[34]

Wu CW, Chen C-L, Liu P-Y, et al. (2011) Empirical evaluations of slice-timing, smoothing, and normalization effects in seed-based, resting-state functional magnetic resonance imaging analyses. Brain Connectivity 1(5): 401-10.

[35]

Yan C-G, Wang X-D, Zuo X-N, et al. (2016) DPABI: data processing & analysis for (Resting-State) Brain imaging. Neuroinform 14(3): 339-51.

[36]

Young IM, Osipowicz K, Mackenzie A, et al. (2022) Comparison of consistency between image guided and craniometric transcranial magnetic stimulation coil placement. Brain Stimul 15(6): 1465- 6.

[37]

Zhang Z, Zhang H, Xie C-M, et al. (2021) Task-related functional magnetic resonance imaging-based neuronavigation for the treatment of depression by individualized repetitive transcranial magnetic stimulation of the visual cortex. Sci China Life Sci 64(1): 96-106.

PDF

76

Accesses

0

Citation

Detail

Sections
Recommended

/

〈 〉