Robotic bronchial sleeve resections: technical details and early results

Marion Durand

Mini-invasive Surgery ›› 2019, Vol. 3 ›› Issue (1) : 35

PDF
Mini-invasive Surgery ›› 2019, Vol. 3 ›› Issue (1) :35 DOI: 10.20517/2574-1225.2019.31
Original Article
review-article

Robotic bronchial sleeve resections: technical details and early results

Author information +
History +
PDF

Abstract

Aim: We report our four-arm robotic bronchial sleeve anatomical lung resection technique and its early results.

Methods: We retrospectively collected all the four-arm robotic sleeve anatomical lung resections we performed in our institution from February 2014 to August 2019. We reported the results as a series of cases.

Results: During that period, 582 robotic procedures were performed by a single surgeon, of which 486 were major anatomical lung resections. From this group, 10 patients (2%) underwent bronchial sleeve resections. All patients were treated on the right lung. Neither conversion nor major events occurred during surgery. The first bronchial sleeve was performed for Patient 219. The mean length of procedure was 164 (± 43) min. One patient died during hospitalization due to a non-related complication (gastric massive bleeding). Three patients had no complications. Six had minor complications (Clavien Dindo Grade 2) resulting in prolonged length of stay. The mean length of stay was 10 (± 5.7) days. No bronchial fistula occurred. All resection margins were R0.

Conclusion: Four-arm robotic bronchial sleeve is a feasible and safe procedure. Telemanipulation surgery offers excellent technical conditions to ensure a hand-sewed anastomosis and R0 resection. The technical principle and dissection are the same as those of open surgery. Patient selection and mastering of the telemanipulation device are mandatory to perform these complex and rare procedures.

Keywords

Lung carcinoma / robotic / surgery / sleeve lobectomy / sleeve segmentectomy

Cite this article

Download citation ▾
Marion Durand. Robotic bronchial sleeve resections: technical details and early results. Mini-invasive Surgery, 2019, 3(1): 35 DOI:10.20517/2574-1225.2019.31

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Li C,Han D,Chen K.Robotic approach to combined anatomic pulmonary subsegmentectomy: technical aspects and early results..Ann Thorac Surg2019;107:1480-6

[2]

Shanahan B,Redmond KC.Robotic sleeve lobectomy-recent advances..J Thorac Dis2019;11:1074-5 PMCID:PMC6531762

[3]

Durand M,Lamonerie L,Zarka V.Four-arm robotic lung resection versus muscle-sparing mini-thoracotomy: retrospective experience..J Thorac Dis2019;11:1433-42 PMCID:PMC6531725

[4]

Durand M.Four-arm robotic sleeve right upper lobectomy..Ann Cardiothorac Surg2019;8:286-7 PMCID:PMC6462548

[5]

Dindo D,Clavien PA.Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey..Ann Surg2004;240:205-13 PMCID:PMC1360123

[6]

Jiao W,Qiu T,Sun X.Robotic bronchial sleeve lobectomy for central lung tumors: technique and outcome..Ann Thorac Surg2019;108:211-8

[7]

Song G,Miao S,Zhao Y.Learning curve for robot-assisted lobectomy of lung cancer..J Thorac Dis2019;11:2431-7 PMCID:PMC6626771

[8]

Reddy RM.Robotic sleeve lobectomy-technically possible but is it being overused?.J Thorac Dis2019;11:S1211-2 PMCID:PMC6560606

[9]

Pages PB,Renaud S,Thomas PA.Sleeve lobectomy may provide better outcomes than pneumonectomy for non-small cell lung cancer. A decade in a nationwide study..J Thorac Cardiovasc Surg2017;153:184-95.e3

[10]

Cerfolio RJ.Robotic sleeve lobectomy: technical details and early results..J Thorac Dis2016;8:S223-6 PMCID:PMC4775256

[11]

Lin MW,Yang SM.Robotic-assisted thoracoscopic sleeve lobectomy for locally advanced lung cancer..J Thorac Dis2016;8:1747-52 PMCID:PMC4958819

[12]

Pan X,Wang R,Shi J.Initial experience of robotic sleeve resection for lung cancer patients..Ann Thorac Surg2016;102:1892-7

[13]

Gu C,Chen Y,Zhao H.Short-term and mid-term survival in bronchial sleeve resection by robotic system versus thoracotomy for centrally located lung cancer..Eur J Cardiothorac Surg2018;53:648-55

[14]

Li C,Han Y,Xiang J.Robotic sleeve resection for pulmonary disease..World J Surg Oncol2018;16:74 PMCID:PMC5880089