Biomechanical characterization of a novel ring connector for sutureless aortic anastomosis
The surgical treatment for aortic diseases remains a challenge for any cardiac surgeon. The use of sutureless ring connector in aortic anastomosis can simplify the procedure and shorten anastomosis time. Therefore, we developed a novel device for sutureless aortic anastomosis. A series of experiments were carried out for tensile and leakproof-capacity assessments to verify the feasibility of the ring connector by using fresh swine aorta samples. In in vivo test, the ring connector was implanted in 6 swine with follow-up of 6 months. Radiographic and pathological studies of the aorta were performed. In the tensile tests, the strength was 32.7±5.9 Newton (N) in the sutureless anastomosis group, compared with 73.3±12.5 N in the control group by traditional manual suture. In the leakproof-capacity assessment, no sign of either leakage or bursting was evident at 280 mmHg of internal pressure in the aorta samples. In in vivo tests, it took 9.47±0.3 minutes for the sutureless anastomosis, compared with 15.58±1.39 minutes for hand-sewn suturing. Insertion was easy and rapid. Radiographic and pathological studies were performed at first month, third month and sixth month after surgery, each time obtained from the two swine, showed patency of the anastomosis and no signs of stenosis, blood leakage, migration or pseudoaneurysm formation, except one paralyzed swine developed of thrombo-occlusion at the site of the sutureless anastomosis. The result indicates that this novel ring connector offers considerable promise for sutureless aortic anastomosis.
aortic diseases / sutureless device / aortic anastomosis / swine
[1] |
Vokrri L, Krasniqi X, Qavdarbasha A,
Pubmed
|
[2] |
Wei J, Chang CY, Chuang YC,
Pubmed
|
[3] |
Yoffe B, Vaysbeyn I, Urin Y,
Pubmed
|
[4] |
Song F, Zhou W, Tang T,
|
[5] |
Nazari S. Expandable device type III for easy and reliable approximation of dissection layers in sutureless aortic anastomosis. Ex vivo experimental study[J]. Interact Cardiovasc Thorac Surg, 2010, 10(2): 161–164
Pubmed
|
[6] |
Nakano Y, Hori Y, Sato A,
Pubmed
|
[7] |
Abou Taam S, Garbé JF, Boufi M,
Pubmed
|
[8] |
Okita Y. Fighting spinal cord complication during surgery for thoracoabdominal aortic disease[J]. Gen Thorac Cardiovasc Surg, 2011, 59(2): 79–90
Pubmed
|
[9] |
Augoustides JG, Stone ME, Drenger B. Novel approaches to spinal cord protection during thoracoabdominal aortic interventions[J]. Curr Opin Anaesthesiol, 2014, 27(1): 98–105
Pubmed
|
[10] |
Panos A, Murith N, Bednarkiewicz M,
Pubmed
|
[11] |
Oz MC, Ashton RC Jr, Singh MK,
Pubmed
|
[12] |
Kawahito K, Adachi H, Yamaguchi A,
Pubmed
|
[13] |
Seguin J R, Frapier J M, Colson P,
|
[14] |
Kawahito K, Adachi H, Yamaguchi A,
Pubmed
|
[15] |
Matsumae M, Oz M C, Lemole G M. A flexible sutureless intraluminal graft that becomes rigid after placement in the aorta[J]. 1990,100(5):787–792.
|
[16] |
Nazari S, Luzzana F, Banfi C,
Pubmed
|
[17] |
Aluffi A, Berti A, Buniva P,
Pubmed
|
[18] |
Shifrin EG, Moore WS, Bell PR,
Pubmed
|
[19] |
Deb S, Martin B, Sun L,
Pubmed
|
[20] |
Saba D, Yilmaz M, Yavuz H,
Pubmed
|
[21] |
Apostolakis EE, Leivaditis VN, Anagnostopoulos C. Sutureless technique to support anastomosis during thoracic aorta replacement[J]. J Cardiothorac Surg, 2009, 4: 66
Pubmed
|
[22] |
Köstering H, Mast WP, Kaethner T,
Pubmed
|
[23] |
Moonen JR, Lee ES, Schmidt M,
Pubmed
|
[24] |
Amaya R, Pierides A, Tarbell JM. The Interaction between Fluid Wall Shear Stress and Solid Circumferential Strain Affects Endothelial Gene Expression[J]. PLoS One, 2015, 10(7): e0129952
Pubmed
|
/
〈 |
|
〉 |