A novel entry point for pedicle screw placement in the thoracic spine

Zhifeng Sun, Kaixiang Yang, Hongtao Chen, Tao Sui, Lei Yang, Dawei Ge, Jian Tang, Xiaojian Cao

PDF(209 KB)
PDF(209 KB)
Journal of Biomedical Research ›› 2018, Vol. 32 ›› Issue (2) : 123-129. DOI: 10.7555/JBR.31.20160037
Original Article
Original Article

A novel entry point for pedicle screw placement in the thoracic spine

Author information +
History +

Abstract

This study was aimed to introduce a novel entry point for pedicle screw fixation in the thoracic spine and compare it with the traditional entry point. A novel entry point was found with the aim of improving accuracy, safety and stability of pedicle screw technique based on anatomical structures of the spine. A total of 76 pieces of normal thoracic CT images at the transverse plane and the thoracic pedicle anatomy of 6 cadaveric specimens were recruited. Transverse pedicle angle (TPA), screw length, screw placement accuracy rate and axial pullout strength of the two different entry point groups were compared. There were significant differences in the TPA, screw length, and the screw placement accuracy rate between the two groups (P<0.05). The maximum axial pullout strength of the novel entry point group was slightly larger than that of the traditional group. However, the difference was not significant (P>0.05). The novel entry point significantly improved the accuracy, stability and safety of pedicle screw placement. With reference to the advantages above, the new entry point can be used for spinal internal fixations in the thoracic spine.

Keywords

entry point / screw placement / thoracic spine / biomechanical stability

Cite this article

Download citation ▾
Zhifeng Sun, Kaixiang Yang, Hongtao Chen, Tao Sui, Lei Yang, Dawei Ge, Jian Tang, Xiaojian Cao. A novel entry point for pedicle screw placement in the thoracic spine. Journal of Biomedical Research, 2018, 32(2): 123‒129 https://doi.org/10.7555/JBR.31.20160037

References

[1]
Gaines RW Jr. The use of pedicle-screw internal fixation for the operative treatment of spinal disorders[J]. J Bone Joint Surg Am, 2000, 82-A(10): 1458–1476
Pubmed
[2]
Roy-Camille R, Saillant G, Mazel C. Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates[J]. Orthop Clin North Am, 1986, 17(1): 147–159
Pubmed
[3]
Khoo LT, Palmer S, Laich DT, Minimally invasive percutaneous posterior lumbar interbody fusion[J]. Neurosurgery, 2002, 51(5 Suppl): S166–S181
Pubmed
[4]
Vassal M, Lonjon G, Knafo S, Surgical treatment of thoracic spine fractures. Outcomes on 50 patients at 23 months follow-up[J]. Orthop Traumatol Surg Res, 2014, 100(5): 475–480
Pubmed
[5]
Amiot LP, Lang K, Putzier M, Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine[J]. Spine (Phila Pa 1976), 2000, 25(5): 606–614
Pubmed
[6]
Belmont PJ Jr, Klemme WR, Dhawan A, In vivo accuracy of thoracic pedicle screws[J]. Spine (Phila Pa 1976), 2001, 26(21): 2340–2346
Pubmed
[7]
Carbone JJ, Tortolani PJ, Quartararo LG. Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: technique and short-term complications[J]. Spine (Phila Pa 1976), 2003, 28(1): 91–97
Pubmed
[8]
Elliott MJ, Slakey JB. Thoracic pedicle screw placement: analysis using anatomical landmarks without image guidance[J]. J Pediatr Orthop, 2007, 27(5): 582–586
Pubmed
[9]
Hyun SJ, Kim YJ, Cheh G, Free hand pedicle screw placement in the thoracic spine without any radiographic guidance: technical note, a cadaveric study[J]. J Korean Neurosurg Soc, 2012, 51(1): 66–70
Pubmed
[10]
Kim YW, Lenke LG, Kim YJ, Free-hand pedicle screw placement during revision spinal surgery: analysis of 552 screws[J]. Spine (Phila Pa 1976), 2008, 33(10): 1141–1148
Pubmed
[11]
Lehman RA Jr, Polly DW Jr, Kuklo TR, Straight-forward versus anatomic trajectory technique of thoracic pedicle screw fixation: a biomechanical analysis[J]. Spine (Phila Pa 1976), 2003, 28(18): 2058–2065
Pubmed
[12]
Kim YJ, Lenke LG, Bridwell KH, Free hand pedicle screw placement in the thoracic spine: is it safe[J]? Spine (Phila Pa 1976), 2004, 29(3): 333–342., discussion 342
Pubmed
[13]
Sclafani JA, Regev GJ, Webb J, Use of a quantitative pedicle screw accuracy system to assess new technology: Initial studies on O-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion[J]. SAS J, 2011, 5(3): 57–62
Pubmed
[14]
Shin BJ, James AR, Njoku IU, Pedicle screw navigation: a systematic review and meta-analysis of perforation risk for computer-navigated versus freehand insertion[J]. J Neurosurg Spine, 2012, 17(2): 113–122
Pubmed
[15]
Magerl F, Aebi M, Gertzbein SD, A comprehensive classification of thoracic and lumbar injuries[J]. Eur Spine J, 1994, 3(4): 184–201
Pubmed
[16]
Shin BJ, Njoku IU, Tsiouris AJ, Navigated guide tube for the placement of mini-open pedicle screws using stereotactic 3D navigation without the use of K-wires: technical note[J]. J Neurosurg Spine, 2013, 18(2): 178–183
Pubmed
[17]
Youkilis AS, Quint DJ, McGillicuddy JE, Stereotactic navigation for placement of pedicle screws in the thoracic spine[J]. Neurosurgery, 2001, 48(4): 771–778., discussion 778–779.
Pubmed
[18]
Amiot LP, Lang K, Putzier M, Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine[J]. Spine (Phila Pa 1976), 2000, 25(5): 606–614
Pubmed
[19]
Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D. Accuracy of pedicle screw insertion with and without computer assistance: A randomised controlled clinical study in 100 consecutive patients[J]. Eur Spine J 2000;9:235–40.30.
[20]
Laine T, Schlenzka D, Mäkitalo K, Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients[J]. Spine (Phila Pa 1976), 1997, 22(11): 1254–1258
Pubmed
[21]
Liu YJ, Tian W, Liu B, [Accuracy of CT-based navigation of pedicle screws implantation in the cervical spine compared with X-ray fluoroscopy technique][J]. Zhonghua Wai Ke Za Zhi, 2005, 43(20): 1328–1330
Pubmed
[22]
Kuklo TR, Lenke LG, O’Brien MF, Accuracy and efficacy of thoracic pedicle screws in curves more than 90 degrees[J]. Spine (Phila Pa 1976), 2005, 30(2): 222–226
Pubmed
[23]
Cinotti G, Gumina S, Ripani M, Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws[J]. Spine (Phila Pa 1976), 1999, 24(2): 114–119
Pubmed
[24]
Seller K, Wahl D, Wild A, Pullout strength of anterior spinal instrumentation: a product comparison of seven screws in calf vertebral bodies[J]. Eur Spine J, 2007, 16(7): 1047–1054
Pubmed
[25]
Weinstein JN, Rydevik BL, Rauschning W. Anatomic and technical considerations of pedicle screw fixation[J]. Clin Orthop Relat Res, 1992, (284): 34–46
Pubmed
[26]
McKinley TO, McLain RF, Yerby SA, Characteristics of pedicle screw loading. Effect of surgical technique on intravertebral and intrapedicular bending moments[J]. Spine (Phila Pa 1976), 1999, 24(1): 18–24., discussion 25
Pubmed
[27]
Barber JW, Boden SD, Ganey T, Biomechanical study of lumbar pedicle screws: does convergence affect axial pullout strength[J]? J Spinal Disord, 1998, 11(3): 215–220
Pubmed
[28]
Karapinar L, Erel N, Ozturk H, Pedicle screw placement with a free hand technique in thoracolumbar spine: is it safe[J]? J Spinal Disord Tech, 2008, 21(1): 63–67
Pubmed
[29]
Panjabi MM, Goel V, Oxland T, Human lumbar vertebrae. Quantitative three-dimensional anatomy[J]. Spine (Phila Pa 1976), 1992, 17(3): 299–306
Pubmed

Acknowledgments

This work was supported by the National Natural Science Foundation of China (Grant #81371968, #81371969,#81401791); the Program for Development of Innovative Research Team in the First Affiliated Hospital of NJMU (No. IRT-015), and a project funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions.

RIGHTS & PERMISSIONS

2017 2017 by the Journal of Biomedical Research.
PDF(209 KB)

Accesses

Citations

Detail

Sections
Recommended

/