Unexpected co-arctation of aorta detected by transesophageal echocardiography during patent ductus arteriosus ligation

Frontiers of Medicine ›› 2013, Vol. 7 ›› Issue (2) : 270-273.

PDF(298 KB)
PDF(298 KB)
Frontiers of Medicine ›› 2013, Vol. 7 ›› Issue (2) : 270-273. DOI: 10.1007/s11684-013-0261-7
CASE REPORT
CASE REPORT

Unexpected co-arctation of aorta detected by transesophageal echocardiography during patent ductus arteriosus ligation

作者信息 +

Unexpected co-arctation of aorta detected by transesophageal echocardiography during patent ductus arteriosus ligation

Author information +
History +

Abstract

In the presence of a large patent ductus arteriosus (PDA), aortic co-arctation (CoA) cannot be diagnosed clinically because PDA masks the clinical features. This condition impedes the identification of CoA by transthoracic echcocardiography. However, the closure of PDA can result in a severe clinical condition that causes a patient with undiagnosed CoA to suffer from shock and multi-organ failure. In this article, a case of PDA was presented, in which transesophageal echocardiography provided full information that could be used as reference to identify and define CoA during PDA ligation surgery.

Keywords

patent ductus arteriosus / aortic co-arctation / transesophageal echocardiography

引用本文

导出引用
. . Frontiers of Medicine. 2013, 7(2): 270-273 https://doi.org/10.1007/s11684-013-0261-7

参考文献

[1]
Kenny D, Hijazi ZM. Coarctation of the aorta: from fetal life to adulthood. Cardiol J 2011; 18(5): 487–495
CrossRef ADS Pubmed Google scholar
[2]
Lu CW, Wang JK, Chang CI, Lin MT, Wu ET, Lue HC, Chen YS, Chiu IS, Wu MH. Noninvasive diagnosis of aortic coarctation in neonates with patent ductus arteriosus. J Pediatr 2006; 148(2): 217-221
CrossRef ADS Pubmed Google scholar
[3]
Becker AE, Becker MJ, Edwards JE. Anomalies associated with coarctation of aorta: particular reference to infancy. Circulation 1970; 41(6): 1067-1075
CrossRef ADS Pubmed Google scholar
[4]
Elseed AM, Elliot AS, Matthias P. Manifestation of juxtaductal coarctation after surgical ligation of persistent ductus arteriosus in infancy. Br Heart J 1974; 36(7): 687-692
Pubmed
[5]
Song H, Liu F, Dian K, Liu J. Echo rounds: intraoperative transesophageal echocardiography-guided patent ductus arteriosus ligation in an asymptomatic nonbacterial endocarditis patient. Anesth Analg 2010; 111(4): 878-880
Pubmed
[6]
Yang PL, Wong DT, Dai SB, Song HB, Ye L, Liu J, Liu B. The feasibility of measuring renal blood flow using transesophageal echocardiography in patients undergoing cardiac surgery. Anesth Analg 2009; 108(5): 1418-1424
CrossRef ADS Pubmed Google scholar

版权

2014 Higher Education Press and Springer-Verlag Berlin Heidelberg
PDF(298 KB)

Accesses

Citation

Detail

段落导航
相关文章

/