Sizing of hybrid PMSG-PV system for battery charging of electric vehicles

PDF(305 KB)
PDF(305 KB)
Frontiers in Energy ›› 2015, Vol. 9 ›› Issue (1) : 68-74. DOI: 10.1007/s11708-015-0349-7

作者信息 +

Sizing of hybrid PMSG-PV system for battery charging of electric vehicles

Author information +
History +

Abstract

The number of electric vehicles are increasing in the society as they are considered as zero emission vehicles and also because conventional fuels are becoming expensive. Additional electrical power should be produced to meet the energy requirement of this increase in electric vehicle population. To use the existing grid infrastructure without any failure, installing distributed generator at secondary distribution network is essential. In this work, sizing of wind-driven permanent magnet synchronous generator—photovoltaic hybrid distributed generating system has been attempted to meet the energy demand of electric vehicles of a particular residential area. Different feasible combinations for wind generator capacity and photovoltaic capacity are obtained to satisfy the additional energy requirement. Results are analyzed based on energy, financial payback periods and daily power profile of the hybrid system. Based on this analysis, the sizes of wind generator and photovoltaic array have been chosen to meet the energy demand of electric vehicles of that particular residential locality.

Keywords

electric vehicles / hybrid PMSG-PV system / smart grid

引用本文

导出引用
. . Frontiers in Energy. 2015, 9(1): 68-74 https://doi.org/10.1007/s11708-015-0349-7

参考文献

[1]
Cai Z, Ou X, Zhang Q, Zhang X. Full lifetime cost analysis of battery, plug-in hybrid and FCEVs in China in the near future. Frontiers in Energy, 2012, 6(2): 107–111
CrossRef ADS Google scholar
[2]
Zhang P, Qian K, Zhou C, Stewart B G, Hepburn D M. A methodology for optimization of power systems demand due to electric vehicle charging load. IEEE Transactions on Power Systems, 2012, 27(3): 1628–1636
CrossRef ADS Google scholar
[3]
Richardson P, Flynn D, Keane A. Optimal charging of electric vehicles in low-voltage distribution systems. IEEE Transactions on Power Systems, 2012, 27(1): 268–279
CrossRef ADS Google scholar
[4]
Clement-Nyns K, Haesen E, Driesen J. The impact of charging plug-in hybrid electric vehicles on a residential distribution grid. IEEE Transactions on Power Systems, 2010, 25(1): 371–380
CrossRef ADS Google scholar
[5]
Indiamart. Energy Alternatives India. 2014-03, http://www.indiamart.com/energy-alternativesindia/
[6]
Daniel S A, Ammasaigounden N. A novel hybrid isolated generating system based on PV fed inverter-assisted wind-driven induction generators. IEEE Transactions on Energy Conversion, 2004, 19(2): 416–422
CrossRef ADS Google scholar
[7]
Luna-Rubio R, Trejo-Perea M, Vargas-Vázquez D, Ríos-Moreno G J. Optimal sizing of renewable hybrids energy systems: a review of methodologies. Solar Energy, 2012, 86(4): 1077–1088
CrossRef ADS Google scholar
[8]
Erdinc O, Uzunoglu M. Optimum design of hybrid renewable energy systems: overview of different approaches. Renewable & Sustainable Energy Reviews, 2012, 16(3): 1412–1425
CrossRef ADS Google scholar
[9]
Diaf S, Diaf D, Belhamel M, Haddadi M, Louche A. A methodology for optimal sizing of autonomous hybrid PV/wind system. Energy Policy, 2007, 35(11): 5708–5718
CrossRef ADS Google scholar
[10]
Ekren O, Ekren B Y. Size optimization of a PV/wind hybrid energy conversion system with battery storage using simulated annealing. Applied Energy, 2010, 87(2): 592–598
CrossRef ADS Google scholar
[11]
Kaabeche A, Belhamel M, Ibtiouen R. Sizing optimization of grid-independent hybrid photovoltaic/wind power generation system. Energy, 2011, 36(2): 1214–1222
CrossRef ADS Google scholar
[12]
Belmili H, Haddadi M, Bacha S, Almi M F, Bendib B. Sizing stand-alone photovoltaic–wind hybrid system: techno-economic analysis and optimization. Renewable & Sustainable Energy Reviews, 2014, 30: 821–832
CrossRef ADS Google scholar
[13]
Kaldellis J K, Zafirakis D. Optimum sizing of stand-alone wind-photovoltaic hybrid systems for representative wind and solar potential cases of the Greek territory. Journal of Wind Engineering and Industrial Aerodynamics, 2012, 107–108: 169–178
CrossRef ADS Google scholar
[14]
Celik A N. Techno-economic analysis of autonomous PV-wind hybrid energy systems using different sizing methods. Energy Conversion and Management, 2003, 44(12): 1951–1968
CrossRef ADS Google scholar
[15]
Caballero F, Sauma E, Yanine F. Business optimal design of a grid-connected hybrid PV (photovoltaic)-wind energy system without energy storage for an Easter Island's block. Energy, 2013, 61: 248–261
CrossRef ADS Google scholar
[16]
Bayod-Rújula Á A, Haro-Larrodé M E, Martínez-Gracia A. Sizing criteria of hybrid photovoltaic–wind systems with battery storage and self-consumption considering interaction with the grid. Solar Energy, 2013, 98(Part C): 582–591
CrossRef ADS Google scholar
[17]
Bae S, Kwasinski A. Dynamic modeling and operation strategy for a microgrid with wind and photovoltaic resources. IEEE Transaction on Smart Grid, 2012, 3(4): 1867–1876
CrossRef ADS Google scholar
[18]
Chen Y M, Liu Y C, Hung S C, Cheng C S. Multi-input inverter for grid connected hybrid PV/wind power systems. IEEE Transactions on Power Electronics, 2007, 22(3): 1070–1077
CrossRef ADS Google scholar
[19]
Chiang H C, Ma T T, Cheng Y H, Chang J M, Chang W N. Design and implementation of a hybrid regenerative power system combining grid-tie and uninterruptible power supply functions. IET Renewable Power Generation, 2010, 4(1): 85–99
CrossRef ADS Google scholar
[20]
Hocaoglu F O, Gerek O N, Kurban M. The effect of model generated solar irradiation data usage in hybrid (wind–PV) sizing studies. Energy Conversion and Management, 2009, 50(12): 2956–2963
CrossRef ADS Google scholar
[21]
Rajan Singaravel M M, Arul Daniel S. Studies on battery storage requirement of PV fed wind-driven induction generators. Energy Conversion and Management, 2013, 67: 34–43
CrossRef ADS Google scholar
[22]
Peng J, Lu L, Yang H. Review on life cycle assessment of energy payback and greenhouse gas emission of solar photovoltaic systems. Renewable & Sustainable Energy Reviews, 2013, 19: 255–274
CrossRef ADS Google scholar
[23]
Lu L, Yang H X. Environmental payback time analysis of a roof-mounted building-integrated photovoltaic (BIPV) system in Hong Kong. Applied Energy, 2010, 87(12): 3625–3631
CrossRef ADS Google scholar
[24]
Kaldellis J K, Zafirakis D, Kondili E. Energy pay-back period analysis of stand-alone photovoltaic systems. Renewable Energy, 2010, 35(7): 1444–1454
CrossRef ADS Google scholar
[25]
Tremeac B, Meunier F. Life cycle analysis of 4.5 MW and 250 MW wind turbines. Renewable & Sustainable Energy Reviews, 2009, 13(8): 2104–2110
CrossRef ADS Google scholar
[26]
Martínez E, Sanz F, Pellegrini S, Jiménez E, Blanco J. Life cycle assessment of a multi-megawatt wind turbine. Renewable Energy, 2009, 34(3): 667–673
CrossRef ADS Google scholar
[27]
Guezuraga B, Zauner R, Pölz W. Life cycle assessment of two different 2 MW class wind turbines. Renewable Energy, 2012, 37(1): 37–44
CrossRef ADS Google scholar
[28]
White S W, Kulcinski G L. Birth to death analysis of the energy payback ratio and CO2 gas emission rates from coal, fission, wind, and DT-fusion electrical power plants. Fusion Engineering and Design, 2000, 48(3–4): 473–481
CrossRef ADS Google scholar
[29]
Alhasawi F B, Milanovic J V. Techno-economic contribution of FACTS devices to the operation of power systems with high level of wind power integration. IEEE Transactions on Power Systems, 2012, 27(3): 1414–1421
CrossRef ADS Google scholar
[30]
Bernal-Agustín J L, Dufo-López R. Economical and environmental analysis of grid connected photovoltaic systems in Spain. Renewable Energy, 2006, 31(8): 1107–1128
CrossRef ADS Google scholar

版权

2015 Higher Education Press and Springer-Verlag Berlin Heidelberg
PDF(305 KB)

Accesses

Citation

Detail

段落导航