%A Shoudao HUANG, Xuan WU, Xiao LIU, Jian GAO, Yunze HE %T Overview of condition monitoring and operation control of electric power conversion systems in direct-drive wind turbines under faults %0 Journal Article %D 2017 %J Front. Mech. Eng. %J Frontiers of Mechanical Engineering %@ 2095-0233 %R 10.1007/s11465-017-0442-1 %P 281-302 %V 12 %N 3 %U {https://journal.hep.com.cn/fme/EN/10.1007/s11465-017-0442-1 %8 2017-08-04 %X

Electric power conversion system (EPCS), which consists of a generator and power converter, is one of the most important subsystems in a direct-drive wind turbine (DD-WT). However, this component accounts for the most failures (approximately 60% of the total number) in the entire DD-WT system according to statistical data. To improve the reliability of EPCSs and reduce the operation and maintenance cost of DD-WTs, numerous researchers have studied condition monitoring (CM) and fault diagnostics (FD). Numerous CM and FD techniques, which have respective advantages and disadvantages, have emerged. This paper provides an overview of the CM, FD, and operation control of EPCSs in DD-WTs under faults. After introducing the functional principle and structure of EPCS, this survey discusses the common failures in wind generators and power converters; briefly reviewed CM and FD methods and operation control of these generators and power converters under faults; and discussed the grid voltage faults related to EPCSs in DD-WTs. These theories and their related technical concepts are systematically discussed. Finally, predicted development trends are presented. The paper provides a valuable reference for developing service quality evaluation methods and fault operation control systems to achieve high-performance and high-intelligence DD-WTs.